6.0 INSTALLATION
Electrical Safety and Advice Regarding Supplementary Electrical Protection
Commercial kitchens and foodservice areas are environments where electrical appliances
may be located close to liquids, or operate in and around damp conditions, or where
restricted movement for installation and service is evident.
The installation and periodic inspection of the appliance should only be undertaken by a
qualified, skilled and competent electrician; and connected to the correct power supply
suitable for load as stipulated by the appliance data label.
The electrical installation and connections should meet the necessary requirements to local
electrical wiring regulations and electrical safety guidelines.
We recommend:-
Supplementary electrical protection with use of a residual current device (RCD).
Fixed wiring appliances incorporate a locally situated switch disconnector to connect
to, which is easily accessible for switching off and safe isolation purposes. The switch
disconnector must meet the specification requirements of IEC 60947.
6.1 SITING / CLEARANCES
CAUTION: WALLS CLOSER THAN 150mm TO THE APPLIANCE
MUST BE NON COMBUSTABLE. IF SUITING THE NECESSARY
CLEARANCES TO ANY CUMBUSTIBLE WALL MUST BE THE
LARGEST FIGURE GIVEN FOR INDIVIDUAL APPLIANCES
INSTRUCTIONS.