15
6.4 GAS SUPPLY & CONNECTION
6.4.1 Installation pipe work should be fitted in accordance with local / national standards.
The pipe work must not be smaller than unit gas inlet connection. If using flexible
hosing, the hose must be sized to conform to BS 6173 and the length must not exceed
1.5m. An isolating valve must be located close by for shut-down during an emergency
or servicing. An inlet manifold is supplied with to enable connection to ¾” BSP inlets.
6.4.2 If flexible hose is used, it shall comply with national requirements. These must be
periodically examined and replaced as necessary. A retention chain must also be
attached to the rear of the appliance.
6.4.3
Natural Gas Appliance
- Supplied governor must be fitted to the rear of the appliance.
(see section 8.9)
6.4.4 The installation should be checked for gas tightness and purged as specified in
IGE/UP/1.
6.5 ELECTRIC SUPPLY & CONNECTION
G3845F Only
- A suitable supply cord is supplied that conforms to BSEN 50525-2-11, cable
type H05VV-F. This appliance is designed to, and must, be connected to suitably rated
isolator. It is recommended that the isolator be rated to 230V at 13A,
with contact separation
of at least 3mm
in all poles
. If cord is damaged, it must be replaced by a suitably qualified
person.
Live 1 ( Phase 1)
Brown
Neutral
Blue
Earth
Yellow/Green
THIS APPLIANCE MUST BE EARTHED.