FLUE PIPES
A flue pipe should only be used to connect an appli-
ance to a chimney and should not pass through any
roof space.
Flue pipes in cast iron, stainless steel or enamelled
steel are suitable for use on this appliance. All flue
pipes must meet the requirements of the relevant
standards.
Flue pipes with spigot and socket joints should be fit-
ted with the socket uppermost.
Clearance to combustibles must be adhered to
when fitting the flue pipe.
3
Fig.4
FLUE EXIT (TOP & REAR)
The stove is not designed to allow the chimney be
cleaned through the stove. A means must be provid-
ed to clean the chimney such as a soot box/access
door in the flue for cleaning. See Fig.3 for recom-
mended locations. Fit it to the stove as shown in
Fig.3.
The stove is supplied with a reversible flue spigot for
use with both top outlet and rear outlet. Fit the spig-
ot as per Fig.4 for top outlet and as per Fig.5 for rear
outlet.
Fig.3
Flue Liner
Sleeve
Flue Pipe
Possible
Positions
for access
Flue
Soot Door
Appliance Flue
Outlet
Appliance
Debris Collection
space
FLUE ORIENTATION ASSEMBLY
Fig.2
Flue Spigot
Blanking
Plate