SECTION 1 - INSTALLATION

1.2 SITING
The appliance should be installed on a table, counter,

or similar surface. Alternatively it can be mounted on

the purpose designed floor stand supplied by Falcon.
Should it require to be positioned in close proximity to

a wall, partition, etc., a minimum clearance of 25mm

at the reae and sides is recommended.
A vertical clearance between the the plate and any

overlying combustible surface of 900mm should be

allowed. Fire Regulations must be complied with.

1.3 ELECTRICAL SUPPLY
These units are designed for use on AC supplies

only. The E350/34 Griddle plate is for use on single

phase supplies only. The E350/35 model can be used

on single-phase or alternatively on a 2-phase supply.
1.3.1 Supply Connection
The cable entry is located at the rear of the appliance

and is suitable for 20mm conduit. A suitable isolating

switch must be provided with a minimum contact

separation of 3 mm in all poles. All wiring must be

executed in accordance with the regulations listed on

the cover of the manual.
These appliances must be earthed.
A suitable terminal is provided for this purpose and

must be used for this purpose.
Note
When connecting the E350/35, the line terminals

must be connected using the link(s) provided. See the

diagram below.

N

L1

L2

L3

Supply Cables

N

L1

1.4 ELECTRICAL RATINGS
The electrical rating is as stated on the unit data plate.

SECTION 2 - ASSEMBLY

a) Place the unit in position and carefully level it,

using the feet adjusters if it is to be mounted on a

counter or table. To mount the unit on the purpose

built stand, refer tothe instructions supplied with

the component.

b) The appliance is supplied complete and ready to

be connected to the mains supply.

c) Togain access tothe terminals, pro

ceed as

follows:-

Remove the fat drawer(s).
Remove the two screws in the upper flange of the

control panel.
Allow the panel to drop downward slightly to release

the lower fixings. The arms should be swung out and

the facia panel engages on the arms via the screws

securing the bottom trim.
d) The terminals are now accessible and the supply

cables can be fed through the inbuilt conduit tube.

e) After connecting the mains supply, replace the

control panel and fat drawer. When fitting the

control panel, present it to the location in a dropped

position then raise it vertically to ensure that the

lower fixings are properly engaged. Fit the fat

drawer. Allow the hotplate to heat up and check

that the thermostat operates satisfactorily.

f) After completion of the installation, demonstrate

the method of operation to the kitchen staff. Point

out the location of the isolating switch for use in the

event of an emergency or during routine cleaning.

SECTION 3 - SERVICING

BEFORE ATTEMPTING ANY MAINTENANCE,

SWITCH OFF AT THE MAIN (ISOLATING) SWITCH

AND TAKE STEPS TO ENSURE THAT IT IS NOT

INADVERTENTLY SWITCHED ON.
Warning
Since the cast iron plates are extremely heavy, care

must be exercised when lifting the griddle plate to

carry out maintenance. The initial lifting points are

through the fat escape holes. A suitable batten of

wood should be inserted between the plate and the

front hob rail to support the weight.
Rest the plate on the batten and take a strong grip

below the front edge of the plate. Raise it to the

desired angle for access.
Place a suitable wooden prop, capable of supporting

the weight, below the plate. Ensure that it is securely

anchored to prevent accidental slipping. Make sure

alsothat the appliance base which is much lighter

than the plate cannot move whilst lifting the plate.

UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER

ARE NOT TO BE ADJUSTED BY THE INSTALLER

MODEL

WIDTH

mm

DEPTH

mm

HEIGHT

mm

WEIGHT

kg

WEIGHT

lbs

E350/34

350

650

305

37

82

E350/35

700

650

305

75

166

1.1 MODEL NUMBER, NETT WEIGHTS

and DIMENSIONS