When ordering spares, please quote the model
number, serial number and voltage, as stated on
the data plate.
3.1 CONTROL PANEL - To Remove
Remove the fat drawer, located below the control
panel.
Remove the two screws in the upper flange of the
facia panel.
Allow the panel to drop downward slightly to release
the lower fixings. Remove the panel.
Replace in reverse order.
3.2 THERMOSTAT - To Replace
Remove the control panel as detailed in Sectuon 3.1.
In the controls compartment top there are a number
of hex head screws which hold the plate in position, 2
on the E350/34 and 4 on the E350/35. Remove these
and raise the plate from the front. Prop it up with a
suitable piece of wood. Take care not to strain the
thermostat capillary tube.
Undothe twoscrews which secure the thermostat
phial clamping plate and release the phial.
Pull off the connections to the thermostat, noting their
locations according to the numbers on the wires. Pull
off the thermostat knob and remove the two screws
below to release the thermostat from the panel.
Feed the capillary tube and phial forward through the
rear of the control compartment and remove the
assembly.
Replace in reverse order, taking care to fit the
insulating sleeving over the capillary before fitting
the thermostat.
Ensure that the earth bonding connection is replaced
behind the thermostat fixing lug. After fitting the
thermostat, test the unit using a low setting and check
that the amber light goes out as the thermostat
opens.
Pull off the connections to the thermostat, noting their
locations.
3.3 PILOT LAMPS - To Replace
a) Remove control panel as detailed in Section 3.1.
b) Pull off the lamp connections.
c) Remove the nut securing the lamp at the rear and
remove the lamp.
3.4. HEATING ELEMENTS - To Replace
a) Remove control panel as detailed in Section 3.1.
b) Prop up the hotplate as described in Section 3.2.
c) Remove the element connections.
d) Remove the nuts fixing the element lagging boxes.
e) Remove the clamping plates securing the element.
When fitting a new element, ensure that it is properly
fixed to the underside of the hotplate, located by the
various projections cast into the plate.
Ensure that the element earthing connections are
exactly as they were before replacing the element.