background image

When ordering spares, please quote the model

number, serial number and voltage, as stated on

the data plate.

3.1 CONTROL PANEL - To Remove
Remove the fat drawer, located below the control

panel.
Remove the two screws in the upper flange of the

facia panel.
Allow the panel to drop downward slightly to release

the lower fixings. Remove the panel.
Replace in reverse order.

3.2 THERMOSTAT - To Replace
Remove the control panel as detailed in Sectuon 3.1.
In the controls compartment top there are a number

of hex head screws which hold the plate in position, 2

on the E350/34 and 4 on the E350/35. Remove these

and raise the plate from the front. Prop it up with a

suitable piece of wood. Take care not to strain the

thermostat capillary tube.
Undothe twoscrews which secure the thermostat

phial clamping plate and release the phial.
Pull off the connections to the thermostat, noting their

locations according to the numbers on the wires. Pull

off the thermostat knob and remove the two screws

below to release the thermostat from the panel.
Feed the capillary tube and phial forward through the

rear of the control compartment and remove the

assembly.
Replace in reverse order, taking care to fit the

insulating sleeving over the capillary before fitting

the thermostat.
Ensure that the earth bonding connection is replaced

behind the thermostat fixing lug. After fitting the

thermostat, test the unit using a low setting and check

that the amber light goes out as the thermostat

opens.
Pull off the connections to the thermostat, noting their

locations.

3.3 PILOT LAMPS - To Replace
a) Remove control panel as detailed in Section 3.1.
b) Pull off the lamp connections.
c) Remove the nut securing the lamp at the rear and

remove the lamp.

3.4. HEATING ELEMENTS - To Replace
a) Remove control panel as detailed in Section 3.1.
b) Prop up the hotplate as described in Section 3.2.
c) Remove the element connections.
d) Remove the nuts fixing the element lagging boxes.
e) Remove the clamping plates securing the element.
When fitting a new element, ensure that it is properly

fixed to the underside of the hotplate, located by the

various projections cast into the plate.
Ensure that the element earthing connections are

exactly as they were before replacing the element.

Reviews: