background image

Code

Error

Cause

Action by user

01

Hardware 

over coil

Unsuitable pan material

Wrong or defective coil

Use suitable pan

Call Service Engineer.

02

No inductor 

current

Inductor connection failure

Call Service Engineer.

03

Heat  sink 

temperature 

too high

Air routes blocked. Fan filter

clogged. Generator 

temperature sensor defective

Clear air routes. Clean fan air

intake filter. If still faulty, 

call Service Engineer.

04

Cooking zone 

temperature too

high or too low

Pan empty

Pan base distorted

Coil temperature sensor faulty

Remove pan, check pan base. Switch

off, allow zone to cool and try again. 

If still faulty, call Service Engineer.

05

Control 

unit failure

Control / switch assembly is

faulty or wired incorrectly

Call Service Engineer.

06

Internal 

temperature 

too high

Air routes blocked. Fan filter

clogged. Temperature sensor

faulty, external heat 

sources too close

Clear air routes. Clean fan filter. 

Remove any external heat source.

If still faulty, call Service Engineer.

07

Cooking zone

temperature 

sensor

Short circuit at 

temperature sensor

Call Service Engineer.

08

Mains phase 

failure 

Fault in mains supply

Call Service Engineer.

10

Communication

error

Failure in LIN or CAN-Bus

No connection between

keyboard and generator

Disconnect from mains. 

Reconnect and test again. 

Call Service Engineer.

11

Initialisation 

error

Failure while

initialising hardware

Wait. Generator will reset every 

30 seconds. Try switching off and on.

Call Service Engineer.

12

Mains current 

failure

Failure while generator

measures mains current

Call Service Engineer.

13

Mains 

connection

error

Mains voltage too high or 

too low

Call Service Engineer.

14

Mains adaptor

error

Mains voltage too high or 

too low

Call Service Engineer.

15

Protective 

electrical circuit

Pan empty,

faulty sensor

Remove pan, switch off and allow

cooking zone to cool.

Call Service Engineer.

ERROR CODE TABLE

7

Summary of Contents for E3913i

Page 1: ...mance of the appliance WARNING THE APPLIANCE MUST BE EARTHED WARNING PERSONS WITH PACEMAKERS SHOULD CONSULT THEIR G P BEFORE OPERATING THIS APPLIANCE THIS UNIT OPERATES AT 18 22KHz AND THIS MAY AFFECT...

Page 2: ...c worn by the user could become hot when in close proximity to cooking zone Do not place credit cards etc on glass ceramic top as data could be wiped Never leave induction hob unsupervised when in use...

Page 3: ...ect use of pans and cooking zones is provided on Pages 4 and 5 OVEN The oven is controlled by a thermostat An amber neon when lit indicates that current is being supplied to the elements This will go...

Page 4: ...er circle markings have been compromised Figure 7 Zone will Operate however 180mm pan Ideal for cooking Although pot is positioned incorrectly whole pan area will cook Outer circle markings have not b...

Page 5: ...cted Note This is also liable to happen if pans are damaged e g large dents Figure 14 Pot base is bowed inward and is NOT FLAT The unit efficiency will be dramatically reduced during cooking It may no...

Page 6: ...ven doors during cooking process If removing food from oven ensure doors are fully open Cooking times are dependant upon the following Pre heat temperature Food temperature e g frozen chilled or ambie...

Page 7: ...lty external heat sources too close Clear air routes Clean fan filter Remove any external heat source If still faulty call Service Engineer 07 Cooking zone temperature sensor Short circuit at temperat...

Page 8: ...to Figure 5 CLEANING THE APPLIANCE General BEFORE ANY CLEANING OPERATION ISOLATE ELECTRICITY AT MAIN SWITCH THE APPLIANCE MUST NEVER BE CLEANED WITH A JET OF WATER OR BE STEAM CLEANED Surfaces are eas...

Page 9: ...9...

Reviews: