background image

The following precautions should be observed by a qualified technician when 
working with batteries.

1.

Remove watches, rings, or other metal objects.

2.

Use tools with insulated handles.

3.

Wear rubber gloves and boots.

4.

Do not lay tools or metal parts on top of batteries

4.

Storing the UPS and Batteries

Should you need to store the UPS for a long period, fully recharge the battery 
just prior to storage and recharge the battery every 6 months by plugging the 
UPS into a power outlet and turning the UPS on. It is recommended that the 
batteries charge for 24 hours after long-term storage.

5.

FCC 

This equipment generates and uses radio frequency energy and if not installed 
and used properly in strict accordance with the manufacturer's instructions, 
may cause interference to radio and television reception. All models covered in 
this manual have been tested and found to comply with the limits for a Class A
computing device, in accordance with the specifications in FCC regulations, 
Part 15, Subpart J, which are designed to provide reasonable protection 
against such interference

.

If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference by one or more of the 
following measures:

a. Reorient or relocate the receiving antenna.
b. Increase the separation between the equipment and the receiver.
c. Connect the equipment into an outlet on a circuit different from that to 

which the receiver is connected.  

d. Consult the dealer or an experienced radio/television technician for 

assistance. 

12

Summary of Contents for ED1000RM-1

Page 1: ...00RM 1 ED2500RM 1 FALCON ELECTRIC INC Irwindale CA 91706 Tel 626 962 7770 Fax 626 962 7720 The information contained herein is the property of FALCON ELECTRIC INC is proprietary confidential and not t...

Page 2: ...am Description 6 Front Panel LED Functions 6 Rear Panel Diagram Description 7 Chapter 4 Communications Interface 8 Signals Interfacing 8 Chapter 5 Operation 9 Step By Step Operating Procedure 9 Operat...

Page 3: ...detergent on the UPS Never attempt to service batteries High voltage exists within the unit which could cause electrical shock Servicing of batteries should be performed or supervised by personnel kn...

Page 4: ...understanding of the product is essential in providing you years of service for your back up power requirements Refer to the cross reference table below to understand which unit with it s power capab...

Page 5: ...d a non linear load which can be very abusive to most power protection equipment and could decrease its life expectancy The FALCON ED unit is specially devised to accept these loads and protect them e...

Page 6: ...epet i t i ve Peak 8 3A 20A 16 7A 38A 20 0A 45 6A 20 9A 47 6A I nputLi ne Pl ug L5 15p L5 30P O ut putDi st r i but i on Connect or s3 4 5 15R Hei ght i n cm 3 5 8 9 W i dt h i n cm Fr ontPanel Chassi...

Page 7: ...he computer or equipment to allow connection of the equipment power plug to the receptacles located on the rear panel of the UPS 4 When installing this UPS into a rack enclosure the following must be...

Page 8: ...failed Should this occur check the load level and correct any overload condition if present During this condition UPS load outlets will be powered by filtered utility bypass power Should the unit not...

Page 9: ...let for Input Line Cord on ED1000 1 only Line cord permenently attached to ED1500 1 and ED2000 1 11 COOLING FANS 2 Cooling fans draw cool air from the outside of the rear panel and exhaust it out thro...

Page 10: ...CHAPTER CHAPTER 4 4 DB 9 COMMUNICATIONS INTERFACE 8...

Page 11: ...up time and the low battery condition varies depending on the amount of load charge on the battery and condition of the battery See SPECIFICATIONS Section for approximate hold up times at 100 and 50...

Page 12: ...ower switch ON at all times and switch your devices OFF individually This will insure that your batteries are always at a maximum charged state The power switch acts as a system ON OFF switch When thi...

Page 13: ...hock Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing the UP...

Page 14: ...th the manufacturer s instructions may cause interference to radio and television reception All models covered in this manual have been tested and found to comply with the limits for a Class A computi...

Page 15: ...ords The RMA number issued must appear on the outside of the shipping carton The original shipping container must be used when returning any ED Series product Falcon Electric will not assume any respo...

Reviews: