background image

EFS 200, EFS 400,
EFS 402 FRYERS

Installation and Operating
Instructions

IMPORTANT

The installer must ensure that the installation of the appliance is in conformity with these instructions and
National Regulations in force at the time of installation. Particular attention MUST be paid to -

BS7671 IEE Wiring Regulations
Electricity At Work Regulations
Health And Safety At Work Act
Fire Precautions Act

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for
the voltages stated on the Data Plate.

WARNING - THIS APPLIANCE MUST BE EARTHED

On completion of the installation these instructions should be left with the Engineer-in-Charge for reference
during servicing. Further to this, The Users Instructions should be handed over to the User, having had a
demonstration of the operation and cleaning of the appliance.

IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND
COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY
RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.

PREVENTATIVE MAINTENANCE CONTRACT

In order to obtain maximum performance from this unit we would recommend that a Maintenance Contract be
arranged with FALCON SERVICE LINE. Visits may then be made at agreed intervals to carry out adjustments
and repairs. A quotation will be given upon request to the FALCON SERVICE LINE contact numbers below.

Falcon Catering Equipment
Head Office and Works

PO Box 37, Foundry Loan, Larbert
Stirlingshire, Scotland FK5 4PL

Service Line Contact

PHONE

- 01438 751111

FAX

- 01438 369900

Summary of Contents for EFS 200

Page 1: ...ence during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE...

Page 2: ...feet with adjustable screws 27 mm fork wrench To change the height from 900 mm to 850 mm or vice versa b Minimum distances to be observed between the fryer and the wall or other units at the rear 30 m...

Page 3: ...connect to a main switch with all the poles isolated minimum distance of the contacts 3 mm The connection cable should at least be an H05RN F type Fuse Sizes denotes 2 cables denotes 1 cable 5 Control...

Page 4: ...ry to add oil during operation use cold oil Pour it into the pan very slowly to avoid splashing such a condition can cause a risk of bruns Never mix fresh oil or fat with an old frying medium 7 Warnin...

Page 5: ...15 C and automatically cut off the power supply If the safety thermostat stops the machine several times in succession call Falcon Service line Notice The safety thermostat can only be reset after the...

Page 6: ...the drain pipe 5 11 1 4 Cleaning of the Oil Pumping System The oil receptacle 9 and the filters 6 7 can be removed from the drawer 8 and put into the dishwasher Note Before refilling fresh oil or fat...

Page 7: ...from O to select a temperature OK 1 or 2 wires of the control probe not connected 1 or 2 wires of the control probe broken Wrong connection of the control probe Error indication after 15 sec at fat m...

Page 8: ...nde L1 L2 L3 N N PE K21 1 3 5 2 4 6 1 3 5 2 4 6 Corps de chauffe R1 6 X11 K11 S1 S curit Travail 1 2 3 4 5 6 7 1 2 SW 21 3 3 1 1 L 2 N 4 PE WIRING DIAGRAM THREE PHASE CONNECTION 3L N PE Description Ma...