background image

RZZ 84 Ref. 2

G1532 STEAKHOUSE GRILL

INSTALLATION and

SERVICING INSTRUCTIONS

These Appliances must be installed and serviced by a competent person as stipulated by the Gas

Safety (Installation & Use) Regulations.

IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions and

National Regulations in force at the time of installation. Particular attention MUST be paid to -

Gas Safety (Installation & Use) Regulations
Health And Safety At Work etc. Act
Local and National Building Regulations
Fire Precautions Act

These Appliances have been CE-marked on the basis of compliance with the Gas Appliance Directive for the

Countries, Gas Types and Pressures as stated on the Data Plate.

WARNING - TO PREVENT SHOCKS, ALL APPLIANCES WHETHER

GAS OR ELECTRIC, MUST BE EARTHED

On completion of the installation, these instructions should be left with the Engineer-in-Charge for reference

during servicing. Further to this, The Users Instructions should be handed over to the User, having had a

demonstration of the operation and cleaning of the appliance.

IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND

COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY

RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.

PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a Maintenance Contract be

arranged with FALCON SERVICE LINE. Visits may then be made at agreed intervals tocarry out adjustments

and repairs. A quotation will be given upon request to the FALCON SERVICE LINE contact numbers below.

Falcon Foodservice Equipment

HEAD OFFICE AND WORKS
PO Box 37, Foundry Loan, Larbert.

Stirlingshire. Scotland. FK5 4PL
AFE SERVICE LINE CONTACT -
PHONE - 01438 751111

FAX - 01438 369900

Detailed recommendations are contained in

Institute of Gas Engineers published

documents :
IGE/ UP/ 1, IGE/ UP/ 2, BS6173 and BS5440

Summary of Contents for G1532

Page 1: ...be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of...

Page 2: ...harges vertically from the top of the unit There must be no direct connection of the flue to a mechanical extraction system or the outside air Positioning the grill below a ventilated canopy is the mo...

Page 3: ...st below Brander Drip Trough Brander Plate Grid Shelf Drip Tray Gas Governor Natural Gas only Additionally 6 refractory plaques 4 centre support bars of double construction and 4 end support bars Appl...

Page 4: ...crew positions Remove the shelf and d r i l l t h e w a l l t o accomodate suitable plugs for No 8 screws Firmly secure the shelf in position Place the grill on the shelf and place screws through hole...

Page 5: ...rner parts CROSS LIGHT satisfactorily f Turn the control to the LOW FLAME position and check that the flame cone reduces in length Note LOW FLAME position is set at factory Re setting is NOT necessary...

Page 6: ...vidual ports may be cleared with a suitable metal instrument Dislodged material should then be shaken out of the open burner end Should it become necessary to wash the burner s ensure that they are co...

Page 7: ...er with Pilot 3 8 GOVERNOR 3 8 1 General The governor will normally require little servicing Before proceeding with any inspection or servicing TURN OFF THE GAS AT THE ISOLATING COCK 3 8 2 Procedure C...