1
2
SECTION 5 - TROUBLESHOOTING and CRITICAL DIMENSIONS
5 . 1 TROUBLESHOOTING
G2845F
PROBLEM -
No power
.
Action:
a)
Check power is being supplied to unit.
b)
Check temperature limit thermostat has not tripped (Refer to Section 2.6).
G2844F
PROBLEM
- No power
Cause:
Circuit breaker off.
Solution:
Check and reset.
Cause:
Appliance not plugged in.
Solution:
Plug cord in.
Cause:
Defective 24V AC transformer.
Solution:
Replace transformer and/or controller.
PROBLEM
- No sound
Cause:
Inoperable speaker.
Solution:
Replace controller.
PROBLEM
– Button
Cause:
Inoperable key.
Solution:
Replace controller.
PROBLEM:
PROB is displayed.
Cause:
Defective temperature probe.
Solution: Replace temperature probe
Cause:
Probe not plugged in
Solution: Plug probe in
PROBLEM:
Reading Wrong Temperature
Cause:
Defective temperature probe.
Solution:
Replace temperature probe.
PROBLEM:
Not Heating.
Cause:
Check gas circuit.
Solution:
Replace defective part.
Cause:
Defective controller.
Solution:
Replace controller.
Summary of Contents for G2844F
Page 25: ...25 SECTION 11 G2844F CIRCUIT DIAGRAM...
Page 26: ...G2845F CIRCUIT DIAGRAM...
Page 27: ...27 G2844F WIRING DIAGRAM...
Page 28: ...G2845F WIRING DIAGRAM...