background image

SECTION 1 - GENERAL DESCRIPTION
The 350/1 open-top range and G350/2 solid-top

range are two floor standing ranges in the Falcon

350 series. All individual units comprising the Series

are of modular dimensions, enabling suites of

appliances to be installed in a matching line. Some

units are for "counter" mounting, meaning that they

can be installed either on a table or similar, or

alternatively on purpose-made stands, supplied by

Falcon, which ensure perfect matching of hob- height

when installed with floor-standing appliances such as

the ranges.
The G350/1 is a range with 4 open-top burners each

4.3kW(14,700 Btu/hr) heat rating, controlled by safety

taps.
The oven, fitted two doors, is heated by a

thermostatically controlled burner of 4.75kW

(16,200 Btu/hr), protected by a flame failure device

and equipped with push-button ignition.
The oven has a nominal volume of approximately

0.09m

3

(3.26ft

3

) and is supplied with two wire

grid shelves. Five shelf positions are provided.
The G350/2 solid top range has an oven identical to

the G350/1 , but has a heavy-duty solid-top. The solid

top consists of the traditional centre ring and side

fillings and is heated by a single burner of 7.7kW

(26,800 Btu/hr) capacity. It is controlled by a

combined on/off tap and flame-failure device, ignition

of the burner being by a manually-lit pilot. The tap has

indented positions for full flame and "simmer".

Open Top Taps

Oven Control

(Thermostat)

Spark Igniter

Flame Failure

Button (in Front

Button (in Front

Frame behind

Frame behind

LH Door)

RH Door)

Figure 1 - Open Top Range

Solid Top Control

(Thermostat)

Oven Control

(Thermostat)

Spark Igniter

Flame Failure

Button (in Front

Button (in Front

Frame behind

Frame behind

LH Door)

RH Door)

Figure 2 - Solid Top Range

SECTION 2 - LIGHTING and OPERATIONS
2.1 Open Top
All four burners are equally rated and may be used for

fast boiling or simmering. The pan supports, which

are interchangeable, will safely accommodate pans

from125mmdiameter upwards.
The gas taps are of the safety type and include a

flame failure device.
To Light The Burner
Identify appropriate tap by observing the facia panel

marker . Push the tap knobs inwards then turn fully

anti-clockwise to the FULL FLAME setting and hold

the control knob in for approximately 20 seconds

whilst applying a lit match or taper to burner head rim.

The knob can then be turned anti-clockwise to reduce

flame, if desired.
To Turn The Burner OFF
Simply turn knob clockwise as far as it will go

(see Figure 3).

OFF

FULL ON

SIMMER

(turn anti-clockwise)

(turn further

anti-clockwise)

Figure 3

2.2 Solid Top
Warning
If pilot is extinguished intentionally or unintentionally,

no attempt to re-light the gas should be made until at

least 3 minutes have elapsed.
The procedures are as follows -
Lighting The Burner (Refer to Figure 4)
1. Remove solid-top centre ring using special tool

provided.

2. Have a lit taper or match ready in one hand.
3. With other hand, push in control knob and turn it

anti-clockwise until mark on knob is opposite

ignition symbol.

4. Apply light to pilot, still keeping knob pushed in.
5. After about 20 seconds, release knob, pilot should

remain alight. If not, push in control knob and turn

clockwise to OFF position. Wait 3 minutes, then

repeat fromstep 2.

6. With pilot flame established, replace solid top

centre ring.

7. Push knob in again and turn it anti-clockwise to

FULL FLAME symbol thus lighting burner.