Model

Natural

Propane

G350/7 & 7P

5.2kW

4.65kW

G350/8 & 8P 2 x 5.2kW 2 x 4.65kW

SECTION 1 - INSTALLATION

1.2 SITING
The griddles can be installed on a table, counter top

or alternatively upon a purpose-made stand.
The unit can be positioned to within 75mm of a

combustible wall at the back and sides. There should

be a minimum vertical clearance of 900mm above top

edge of appliance flue to any overhanging

combustible surface.
Important
If unit is tobe installed with other matching appliances

of the Falcon 350 series, the instructions for all units

must be consulted to determine the necessary

clearance to any combustible rear wall or overlying

surface. Some appliances require greater clearances

than others, and the largest figure quoted in the

individual Instructions will therefore determine

clearance for complete suite of adjoining appliances.

1.3 VENTILATION
Adequate ventilation, whether natural or mechanical,

must be provided to ensure sufficient fresh air for

combustion and for removal of combustion products,

which may be harmful to health. Recommendations

for ventilation for Catering Appliances are given in

BS.5440:2. Further, to ensure sufficient room venti-

lation, guidance on the volume of ventilation air

required for different kinds of catering equipment is

given in the table. For multiple installations the

requirements should be added. Installation should

be made in accordance with local and/ or national

regulations applying at the time, and a competent

installer must be employed.
The appliance flue discharges vertically through grille

at rear of hob. There must be no direct connection of

the flue to any mechanical extraction system or

outside air. Siting appliance under a ventilated

canopy is the ideal arrangement.

1.4 GAS SUPPLY
The incoming service must be of sufficient size to

supply full rate without excessive pressure drop.

A gas meter is connected to service pipe by Gas

Supplier. Any existing meter should be checked,

preferably by Gas Supplier, toensure that the meter

is of adequate capacity to supply the unit, and other

associated equipment. This is particularly important

when a number of units are being installed.
Installation pipework should be fitted in accordance

with IGE/UP/2. The size of the pipes from the meter

to the appliance must be not less than that of the

appliance inlet connection, Rp

1

/

2

(

1

/

2

" BSP female).

An isolating cock must be located close to the

appliance tofacilitate shut-do

wn during an

emergency or routine servicing. The cock must be

easily accessible tothe user. The installation must be

tested for gas-tightness; details are given in

IGE/UP/1. The adjustable governor supplied must

be fitted tonatural gas appliances.

1.5 ELECTRICAL SUPPLY
Not applicable to these appliances.

1.6 WATER SUPPLY
Not applicable to these appliances.

1.7 HEAT INPUTS (net) -

NATURAL and PROPANE GAS

EQUIPMENT

Ventilation Rate Required

m

3

/ min

ft

3

/min

Range, Unit Type

17

600

Pastry Oven

17

600

Fryer

26

900

Grill

17

600

Steak Grill

26

900

Boiling Pan

17

600

Steamer

17

600

Sterilizing Sink

14

500

Bains Marie

11

400

Tea/ Coffee Machine

8.5 - 14

300 - 500

UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER

ARE NOT TO BE ADJUSTED BY THE INSTALLER

MODEL

WIDTH

mm

DEPTH

mm

HEIGHT

mm

WEIGHT

kg

WEIGHT

lbs

G350/7 & 7P

350

650

385

38

85

G350/8 & 8P

700

650

385

73

162

1.1 MODEL NUMBERS, NET WEIGHTS

and DIMENSIONS

A "P" suffix denotes propane operation.