background image

Low flame setting screw

3.6.2 Spark Electrode
a) Remove griddle plate and facia panel.
b) Release thermocouple tubing nut and remove

thermocouple from pilot assembly.

c) Remove spark ignition lead from electrode by

releasing M4 securing nut.

d) Release tubing nut which secures electrode to

pilot assembly and remove electrode.

Replace parts in reverse order.
Note
When re-fitting spark electrode terminal, ensure it is

turned away from manual ignition hole in bulkhead.

3.7 GAS TAP
To gain access to gas control, remove control panel

as detailed in Section 3.2 and proceed as follows:
a) Undonut securing burner feed pipe tocontrol.
b) Release pilot tubing nut from control and ease pilot

tube clear of location.

c) Remove fixings which secure control to float rail.
d) Manoeuvre control to enable thermocouple

removal.

e) Withdraw control.
When replacing control, ensure sealing gasket is in a

serviceable condition and check gas tightness.
To clean and lubricate tap, proceed as follows:
f) Undoscrews that fix front securing plate and at the

same time, hold plate against internal spring

pressure.

g) Carefully withdraw plate, complete with operating

spindle.

h) Withdraw exposed rod, spring, brass washer and

sealing washer. Take care not to lose any of these

small parts.

j)

Withdraw plug and clean it with a soft rag.

Also clean mating hole in control body.

Sparingly re-grease plug with an approved heat

resistant grease.
Re-assemble strictly in reverse order. Take care with

central pin assembly.
i.e. Fit spring topin first, then brass washer and finally

rubber sealing washer.
When inserting assembly intoplug, ensure sealing

washer fits snugly into recess at bottom of hole in

plug.
When re-assembling operating spindle, ensure that

niting pin engages in the plug slot.

Adjusting Low Flame Setting
Low flame setting is adjustable by means of a screw

on control front. Refer to Figure 1 and Section 1.10.2.

If it is necessary to adjust flame, adopt the following

procedure:
k) Turn adjusting screw fully clockwise, then unscrew

approx.

Natural Gas -

1

/

2

to

3

/

4

turn.

Propane Gas -

1

/

3

to

1

/

2

turn.

m) Light burner and turn tolow flame setting.
n) Observe that flame is stable and if required,

carefully adjust screw within the limits given for

satisfactory operation. Turning screw in an

anti-clockwise direction will increase flame and

vice-versa.

On two burner models, both burners require

adjustment.
When replacing control, ensure sealing gasket is in a

serviceable condition and check gas tightness.

Take care not to bend thermocouple tubing to less

than 12mm radius.

3.8 GOVERNOR
This applies toNatural Gas appliances only.
The type of governor used is maintenance free.
Check that blue dust cap covering vent is fitted and in

good condition. This protects breather hole.

SECTION 4 - SPARES

When ordering spare parts, always quote appliance

type and serial number. This information will be found

on the data plate, located at unit rear.
In addition, the serial number is also printed on an

identification label on the unit front.

Reviews: