background image

16

GB

USE

Control Panel 

The hood can be switched on pushing directly onto the requested speed without 

fi

 rstly having to 

select 0/1 button.

KEY

         

 

LED                               FUNCTIONS

L                 

0/1 Light                        Turns lighting on and off.

T1               

0/1 Motor on

                 

First speed.

                    

                                      

When pressed for about 2 seconds the motor is switched off.

T2               

Speed on                       Second speed.

T3               

Speed on                       Third speed.

T4               

Speed Fixed                  Max. speed 

                    

           Flashing              Intensive speed.

                                                                     Suitable for the strongest cooking vapours and odours. 

The function becomes active when the button is pushed 
for about 2 seconds. After 10 minutes of  functioning it 
turns off automatically. This function can be interrupted 
by means of pressing any of the buttons.

S1              

Led

               

Fixed

                  

Indicates that the Metal grease 

fi

 lters saturation alarm 

has been triggered, and the 

fi

 lters need to be washed.  

The alarm is triggered after 100 working hours. 

(Reset; 

check the Maintenance-paragraph)

                                         

Flashing              indicates that the activated charcoal odour 

fi

 lter satu-

ration alarm has been triggered, and the 

fi

 lter has to be 

replaced; the metal grease 

fi

 lters must also be washed.  

The activated charcoal odour 

fi

 lter is triggered after 

200 working hours. 

(Activation and Reset; check the 

Maintenance-paragraph)

                              

L

S1

T1

T2

T3

T4

Summary of Contents for L1 400370

Page 1: ...Instruction Manual GB...

Page 2: ......

Page 3: ...e of aeration must be guaranteed in the room in order to pre vent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry...

Page 4: ...1 Hood Body complete with Controls Light Blower Filters 9 1 Reducer Flange 150 120 mm Ref Q ty Installation Components 12c 2 Screws 2 9 x 6 5 Q ty Documentation 1 Instruction Manual 1 Electric Diagra...

Page 5: ...or a support panel thickness of between 15 mm and 30 mm Cut a fitted opening in the bottom surface of the wall unit as shown Remove the metal grease filters see par on Maintenance Disconnect the filte...

Page 6: ...ng sufficient pipe clamps not supplied Remove any activated charcoal filters RECIRCULATION VERSION AIR OUTLET Drill a hole 120 or 150 mm in the shelf above the hood and connect the hood canopy outlet...

Page 7: ...shed for about 2 seconds After 10 minutes of functioning it turns off automatically This function can be interrupted by means of pressing any of the buttons S1 Led Fixed Indicates that the Metal greas...

Page 8: ...set Switch of the lights and extractor motor Press button T3 for at least 3 seconds until the leds start to flash Cleaning the filters The filters are washable and must be cleaned when led S1 flashes...

Page 9: ...m can be enabled on installation or at a later date Turn the Lights and the suction Motor off Disconnect the Hood using the Main switch or the double pole switch on the mains power sup ply Restore the...