28
28
9. Technical Data
THE COOKER IS CATEGORY:
C; 3+; CatII2L3B/P; CatII2E3B/P; CatII2ELL3B/P; CatII2H3B/P.
It is supplied set for group H natural gas. A conversion kit from NG to LP is packed with the cooker.
INSTALLER:
Please leave these instructions with the User.
DATA BADGE LOCATION:
Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION:
GB, IE, FR, BE, NL, DE, SE, AT, CH.
Connections
Gas
(Rp ½ at rear right-hand side)
Electric
Natural gas
20 mbar
230/400 V 50 Hz
Butane
29 mbar
Propane
37 mbar
See the appliance badge for test pressures.
Dimensions
Height (to top of side panel)
minimum 920 mm
maximum 945 mm
Height (to top of fascia)
minimum 920 mm
maximum 945 mm
Overall width
1082 mm
Overall depth
638 mm to front of fascia; 700 mm over handles
Minimum height above the hotplate
800 mm
Refer to
'Positioning the Cooker'.
Ratings
Hotplate
Bypass Screw*
Natural Gas 20 mb
L.P. Gas
Injector
Injector
Wok burner
57
5.0 kW
165
5.0 kW (357 g/h)
107
Large burner
40
3.0 kW
120
3.0 kW (214 g/h)
82
Small burner
32
1.7 kW
95
1.7 kW (121 g/h)
64
* The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for
Natural gas. For LPG conversion the bypass screws must be screwed all the way down.
Oven Efficiency
Ovens
Left-hand Oven
Right-hand Oven
Multi-function
Forced Air Convection
Maximum power output
2.5 kW
2.5 kW
Energy efficiency class on a scale of A (more efficient) to G (less efficient)
A
A
Energy consumption based on standard load
0.95 kWh
0.99 kWh
Usable volume (litres)
78
81
Size
Large
Large
Time to cook standard load
41 minutes
48 minutes
Surface area of the grid
1400 cm
2
1056 cm
2
Grill
2.3 kW
Maximum total electrical load at 230 V
(approximate total including oven lights, oven fan, etc.)
:
7.4 kW.
Summary of Contents for Mercury 1082 Dual Fuel
Page 1: ...Mercury 1082 Dual Fuel USER GUIDE INSTALLATION INSTRUCTIONS...
Page 4: ...ii...
Page 33: ...29...
Page 34: ...30...
Page 35: ...31...