![background image](http://html1.mh-extra.com/html/falcon/predator-xl3/predator-xl3_owners-manual_3262911005.webp)
-
B. System trigger memory
To warn the user that the system was triggered whilst they were away from the vehicle, after
disarming the system the siren will chirp 4 times, the hazard lights flash 3 times and the LED
will flash to indicate the triggered zone as follows:
1 flash = Plug in sensor 2
nd
stage trigger.
2 flashes = Boot or Bonnet trigger.
3 flashes = Door trigger.
4 flashes = Ignition trigger.
* The trigger memory will be erased after turning the
ignition on.
2.8. Silent Arm and Disarm
Following the steps below will arm or disarm the system without the confirmation chirp:
- With the system disarmed and ignition off, Press buttons #1+2 once, The system will be
armed without the chirp but the hazard lights will still flash once to confirm.
- With system armed, Press the button #1+2 once, the system will be disarmed without the
chirp but the hazard lights will flash twice to confirm.
*
If the programmable feature #1 is set as Off, then the system will always be armed and
disarmed without the chirp confirmation but the hazard lights will still flash once(arm) and
twice(disarm) to confirm.
2.9. Trigger and Alarming
A. 1
ST
stage of sensor trigger
- The siren will chirp 3 times.
B. 2
nd
stage of sensor trigger
- The siren will sound for one cycle.
- The hazard lights will flash for one cycle.
- The LED will flash for 1 cycle (1 flash).
C. Boot or bonnet trigger (opened then closed)
- The siren will sound for 1 cycle.
- The hazard lights will flash for 1 cycle.
- The LED will flash for 1 cycle (2 flashes).
D. Boot or bonnet trigger (opened then not closed)
- The siren will sound for 3 cycles.
- The hazard lights will flash for 3 cycles.
- The LED will flash for 3 cycles (2 flashes).
- After the 3 cycles, the boot/bonnet switch will be bypassed until the boot or bonnet is closed
properly.
E. Door trigger (opened and then closed)
- The siren will sound for 1 cycle.
- The hazard lights will flash for 1 cycle.
- The LED will flash for 1 cycle (3 Flashes).
F. Door trigger (opened and not closed)
- The siren will sound for 3 cycles.
- The hazard lights will flash for 3 cycles.
- The LED will flash for 3 cycles (3 Flashes).
- After the 3 cycles, the door trigger will be bypassed until the door is closed properly.
G. Ignition trigger (on and then off)
- The siren will sound for 1 cycle.
- The hazard lights will flash for 1 cycle.
- The LED will flash for 1 cycle (4 Flashes).
H. Ignition trigger (on and not off)
- The siren will sound for 3 cycles.
- The hazard lights will flash for 3 cycles and pause for 5 sec. until the trigger is cleared.
- The LED will flash for 3 cycles (4 Flashes).
*
1 cycle = 30 or 60 sec. depending on the setting of programmable feature #9.