SECTION 1
– INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE
MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER
Take care when installing or removing cast items, they are heavy items.
Brander Plate
– 7kg
1.1 MODEL NUMBERS, NETT WEIGHT and DIMENSIONS
MODEL
WIDTH
mm
DEPTH
mm
HEIGHT
mm
WEIGHT
kg
G1528
900
600
515
82
1.2 SITING
Each unit must be installed level in a well-lit and draught-free position.
A minimum vertical clearance of 550mm in still air is required above the grill flue top edge to
ensure no overheating of overlying surfaces.
A minimum clearance of 400mm from an adjacent wall at the RH side should be provided to
allow removal of the outer panels for service access. Bearing in mind that the LH side & rear
of the unit is likely to become hot, the grill should be positioned 150mm from any
combustible wall and in a manner which will minimise the risk of being touched accidentally.
Furthermore, a minimum working clearance of 1000 mm from the front face of the grill is
required to operate the grill.
These units can be mounted upon non-combustible bench legs, floor stand or wall brackets.
This appliance should NOT be positioned directly on a table top.
1.3 VENTILATION
The grill MUST be installed level in a well lit and draught free position. Adequate ventilation, whether
natural or mechanical, must be provided to ensure sufficient air for combustion and removal of
combustion products and cooking vapours, which may be harmful to health.
This appliance is to be installed with sufficient ventilation to prevent the occurrence of unacceptable
concentrations of substances harmful to health in the room which they are installed.
The fresh air requirement for this appliance at a rate of 1M³/hour per kW is 13.1 M³ of fresh air per
hour.
Care must be taken not to disturb the air for combustion admission and evacuation of products of
combustion on appliances fitted with open burners.
Recommendations for Ventilation of Catering Appliances are given in BS5440:2.
For multiple installations the requirements for individual appliances should be added
together. Installation should be made in accordance with local and/or national regulations
applying at the time. A qualified installer MUST BE employed.
The appliance flue discharges vertically through the grille at the top of the unit. There must
be no direct connection of the flue to any mechanical extraction system or the outside air.
Siting the unit under a ventilated canopy is the ideal arrangement. Remember, dirty
extraction filters and drip trays may become a fire hazard due to drip-down on to equipment
below. Regular cleaning of extraction filters and drip trays must be carried out.
1.4 GAS SUPPLY
The incoming service must be of sufficient size to supply full rate without excessive pressure
drop. A gas meter is connected to the service pipe by the Gas Supplier. An existing meter
should be checked, preferably by the supplier to ensure that the meter can deal with the rate
of gas supply required.