SUP Series™ UPS

700VA & 1kVA

 

Model Number 

SUP700-1C 

SUP1.0K-1C 

Nominal VA  

700 

1000 

          

Electrical Input  

Nominal AC Voltage  

120V or 230V 

120V or 230V  

Current-Amps   

7  (120V), 3.6  (230V) 

10  (120V), 5.2 ( 230V) 

AC Voltage Window 

-21% to 25% 

Frequency 

50/60 Hz (Auto – Tracking) 

Frequency Range 

47 – 63Hz 

UPS is designed for use on 120V domestic or 230V international utility power with neutral, line and ground connections. 

 

Electrical Output 

Watts  

490 

650 

Nominal AC Voltage  

120V 

120V 

Frequency 

50/60 Hz (Auto-Tracking) 

On-Line Voltage Regulation 

± 8% 

On Battery Voltage Regulation  

± 8% Typical (prior to low battery warning) 

Waveform  

True Sinewave 

Surge Protection 

125 Joules MOV 

Unit Protection 

Short Circuit, Overload & Over Temperature 

Efficiency AC to AC (Typical) 

97%  (120Vac Input), 90% (230Vac Input) 

 

Battery 

DC Voltage 

24V 

24V 

Type 

12V, 7AH x 2  

Lead Acid Maintenance-Free 

12V, 9AH x 2  

Lead Acid Maintenance-Free 

Back Up Time        @ Full Load  
                              @ 1/2 Load 

5 Minutes 

12 Minutes

 

4.5 Minutes 

11 Minutes

 

Recharge Time  

5 Hours to 90% 

Battery times are approximate.  

 
Transfer Time 

Bypass to Inverter  

Black-out, 3ms   /   Brown-out, 0ms 

Inverter to Bypass  

0ms 

 
Electrical Connections 

Input 

1 - 6’  Cord with 5-15P & 

1 – 6’ Cord with Schuko 

1 - 6’  Cord with 5 -15P  & 

1 – 6’ Cord with Schuko 

Output 

(3) 5-15R 

(3) 5-15R  

 
Environmental 

Operating Temperature 

0º C - 40º C (32º F to 104º F)  

Altitude 

7,000 Feet 

Humidity 

10% to 95% Non – Condensing 

Cooling 

Low Velocity Forced Air Fans  

Audible Noise @  1 meter 

< 45dBA 

 

Controls and Indicators 

Control 

One Main Control Button  – UPS On/Off, Self Test, Reset & Silence Alarms 

Selection Control 

Two LCD Metering Scroll Function Select Buttons 

LCD Display 
 

AC Input Voltage, AC Output Voltage, Output Frequenc y, DC Battery Voltage, Internal UPS 

Temperature, 

Timer – Minutes to Shutdown, Hours to Restart, Battery – Remaining Battery Time 

LCD Operational Symbols  

Overload, Load Level, UPS is Loaded, Normal Mode, Buck Mode, Boost Mode, Timer Enabled,  

High Temperat ure, Fan Off, Alarm Off, UPS Fault, Battery Low, Battery Level  

Audible Alarms 

Low Battery, Defective Battery, Low Battery, Overload, Over Temperature, AC Out of Range  

Communications  

RS-232 Serial Port and Contact Closure Signal interface  (Bundled UPSil on 2000 Software) 

 

Mechanical 

Dimensions H x W x D 
                         Inches   (mm) 

 

7.9 x 7.1 x 14.2       (200 x 180 x 360) 

Weight                    lb.    (kg) 

33.1   (15) 

33.1   (15) 

Agency Listing 

UL1778, CUL, FCC Class A  

Note: The UPS will go to Green Mode whenever the output load is under 30 watts. 

Falcon Electric, Inc. -  5106 Azusa Canyon Rd. -  Irwindale, CA 91706 -  800.842.6940 Fax 626.962.7720

www.falconups.com - email:sales@falconups.com

©2004 Falcon

®

Electric, Inc. All rights reserved. Falcon

®

and the Falcon Electric logo are registered trademarks of Falcon Electric, Inc.

All other brand names and trademarks are the property of their respective owners.
The information and specifications stated in this document are subject to change without notice.  01-07-04    MD44034-A

17

Summary of Contents for SUP1.0K-1C

Page 1: ...INC SUP SeriesTM User s Guide 700 1000VA WWW FALCONUPS COM 800 842 6940 SUP700 1C SUP1 0K 1C FALCON ELECTRIC INC Irwindale CA 91706 Tel 626 962 7770 Fax 626 962 7720 OM48031 SUP 01 09 04 Rev A 5116 Az...

Page 2: ...Diagram Description 9 Chapter 4 Operation 11 Turning The UPS On and Off 11 UPS Self Test 11 UPS Overload Condition 11 DC Start Cold Start 11 Green Mode Function 11 Battery Charging 12 UPS Reset 12 Re...

Page 3: ...detergent on the UPS Never attempt to service batteries High voltage exists within the unit which could cause electrical shock Servicing of batteries should be performed or supervised by personnel kno...

Page 4: ...isplay gives immediate and detailed UPS and power information without having to connect an expensive monitoring computer An intelligent RS 232 computer interface port is also located on the UPS rear p...

Page 5: ...50Hz European source verify the connected equipment was designed to operate from a 120Vac 50Hz power source This information is stated on the nameplate label located on the model number label located...

Page 6: ...nd will open when the utility fails Pins 5 and 4 are normally open and will close at the low battery indication The UPS will shut down when a 5 12 Vdc voltage is applied across Pins 6 and 7 for three...

Page 7: ...quid Crystal Display LCD is provided Please reference the number designation for the display function and the function descriptions referenced in this manual Refer to pages 6 8 in this manual C Two LC...

Page 8: ...ode The sinewave symbol will be displayed when the UPS is operating normally from the utility line Battery Mode The sinewave and battery symbols will blink when the UPS is operating on its internal ba...

Page 9: ...0 C the UPS will shutdown to prevent damage due to excessive overheating 9 Fan off This symbol is used on special extended backup models only 10 Alarm off The audible alarm has been silenced To reset...

Page 10: ...ill turn on when the display reaches zero Battery Minutes to off The estimated remaining battery run time while in battery backup mode LCD Metering Display Modes use display scroll buttons to change m...

Page 11: ...t the incoming telephone line to one of the jacks Then connect the fax modem or other device to be protected to the other jack 7 Audible Alarms Reference the following table ALARM PERIOD STATUS INDICA...

Page 12: ...if the overload is removed the UPS will automatically turn on again If the overload is still present the UPS will turn off and stay off requiring the UPS be manually restarted Always correct any over...

Page 13: ...to a loss of utility power 7 UPS Reset In the event the UPS will not accept commands and appears to be locked up depress the control button for and hold for ten seconds The UPS CPU will be reset 8 Re...

Page 14: ...r computer room environments the batteries should be replaced every three to five years Never attempt to service batteries High voltage exists within the unit which could cause electrical shock Servic...

Page 15: ...er s instructions may cause interference to radio and television reception All models covered in this manual have been tested and found to comply with the limits for a Class A computing device in acco...

Page 16: ...rds The RMA number issued must appear on the outside of the shipping carton The original shipping container must be used when returning any SUP Series product Falcon Electric will not assume any respo...

Page 17: ...ng the nature of the trouble experienced and the disposition of the equipment after repair The equipment will be returned freight collect by FALCON to the location specified via the best and least exp...

Page 18: ...dity 10 to 95 Non Condensing Cooling Low Velocity Forced Air Fans Audible Noise 1 meter 45dBA Controls and Indicators Control One Main Control Button UPS On Off Self Test Reset Silence Alarms Selectio...

Reviews: