WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
26
A
B
C
ArtNo.311-0010 Injectors
Fig.8-1
A – Jet, B – Internal injector, C – External injector
ArtNo.0102-0001 - Unscrewing
the control valve bypass screw
Fig.8-3
Art No 215-0028 - Handrail fascia fixings
Fig.8-2
Conversion from Natural Gas (1.0 kPa)
to LPG X Propane (2.75 kPa)
n
n
A suitably competent person must perform the
conversion. After conversion the installation must
comply with the relevant regulations and also the
local electricity supply company requirements. Read
the instructions before converting this appliance.
n
n
Failure to convert the appliance correctly could
invalidate any warranty or liability claims and lead
to prosecution.
n
n
When servicing or replacing gas-carrying
components disconnect from the gas supply before
starting operation. Check the appliance is gas sound
after completion.
n
n
DO NOT use reconditioned or unauthorised gas
controls.
n
n
Disconnect from the electricity and gas supply
before servicing.
n
n
Before electrical reconnection, check that the
appliance is electrically safe.
Injectors
Remove the burner caps and heads. Remove the old jets
(Fig.8-1). Fit the new jets (see the
‘Technical Data’
section at the
back of this book for the correct jets). Reassemble in reverse
order.
Tap Adjustment
Classic – Removing the Control Panel
Remove the handrail. Now remove the 2 cross-headed screws
hidden behind the handrail end brackets (Fig.8-2).
Pull off all the control knobs and remove the fixing screws
underneath the control panel.
Lift the control panel and pull forwards, taking care not to
damage or strain the wiring.
Toledo – Removing the Control Panel
Pull off all the control knobs and remove the fixing screws
underneath the control panel.
Slide the control panel to the right and then pull forwards,
taking care not to damage or strain the wiring.
Replacing the Tap Bypass Screws
Unscrew the tap bypass screw (Fig.8-3) and, using a pair of
long nosed pliers, remove. Fit the correct replacement screw
(see the
‘Technical Data’
section for details) and tighten down.
Refit the control panel.
8. Conversion to LP Gas