SG Series UPS - Overview

True Regenerative On-Line Design

As new and innovative technologies have become the backbone of today's businesses, maximum
system availability is critical and downtime is more expensive than ever.  Increasingly, businesses
need a UPS that not only protects against blackouts, but also virtually eliminates more frequent
and subtle power disturbances.  Surges, sags, line noise and brownouts can disrupt proper 
operation of sensitive equipment.  These disturbances may also create unnecessary production,
service, and data recovery costs.

A True Regenerative On-Line UPS provides the highest level of protection against the widest
spectrum of power problems.  The incoming AC utility source is converted to a regulated DC 
voltage. From this DC voltage, a new AC voltage is generated, providing continuous, clean, tightly
regulated power to your equipment. Line-interactive and Off-line designs leave your equipment
connected directly to dirty utility power.  They only provide minimal transient, voltage and backup
protection.  If your equipment operation is "Mission Critical", a true double conversion On-Line
UPS, such as Falcon

®

Electric's SG Series

T

UPS Plus

®

, is the only clear choice.

Input Power Factor Correction

All SG Series UPS Plus models include state-of-the-art Input Power Factor Correction.  This
greatly reduces the amount of current demanded from your building wiring system, yielding a
highly efficient, "building friendly" UPS.

Microprocessor Control

Falcon Electric's SG Series UPS incorporates advanced microprocessor technology.  This 
technology makes possible a high level of internal UPS control and management.  With the 
supplied UPSILON

®

software, all SG Series UPS models support unattended shutdown, manage-

ment, data logging, and self-diagnostics.  The software supports MS Windows

®

95, 98, NT, 2000,

2000 Server, ME, XP, Novell Netware

®

5 & 6, LINUX and FreeBSD.  UPSILON for UNIX is avail-

able as an option and supports most popular UNIX platforms and OS versions.

SNMP/HTTP Remote Management Support

Our SNMP/HTTP Agent board provides remote management and monitoring over any Ethernet
LAN, WAN or the Internet utilizing a 10BaseT-type connection.  The optional SNMP/HTTP agent
installs via an option slot located behind a cover plate on the back panel of every SG Series
model. 

Extended Battery Bank Option

All SG Series models have a continuous duty inverter and support the addition of optional external
battery/charger packs. Whether your application requires a few additional minutes or hours, the
SG Series will be ready. Falcon also offers optional battery charger upgrades for faster 
recharging. Please specify your extended battery requirements at the time of your initial order.
Contact the factory for battery charger options. 

Frequency Converter Option 

With a factory modification at the time of order, any SG Series model can be configured for use as
an international frequency converter.  This makes the SG Series UPS Plus an ideal choice for
worldwide power applications. Without this modification, all SG series models will detect the
incoming utility line frequency and automatically set the output frequency to match the input.

3

All manuals and user guides at all-guides.com

Summary of Contents for UPS Plus SG Series

Page 1: ...reserved All other brand names and trademarks are the property of their respective owners The information stated in this document is subject to change without notice 2007 03 20 Falcon Falcon Electric...

Page 2: ...ion Description 10 Audible Alarms 12 Category One Alarms 12 Category Two Alarms 12 Chapter 4 Front Rear Panel Details 13 Front Panel Overview 13 SG1KRM 1TU Rear Panel Overview 13 SG1KRM 2TU Rear Panel...

Page 3: ...erior Brownout Surge and Transient Protection Internal System Bypass Eliminates Generator Frequency Voltage Drift Microprocessor Control RS 232 Communications UPSILON Monitoring Shutdown Software Opti...

Page 4: ...wledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing the UPS batteries use the same number and type of batteries Allow at least 24 hours...

Page 5: ...Series UPS incorporates advanced microprocessor technology This technology makes possible a high level of internal UPS control and management With the supplied UPSILON software all SG Series UPS mode...

Page 6: ...time of order verify for proper configuration 3 RACKMOUNT UPS MOUNTING INSTRUCTIONS IMPORTANT a NEVER MOUNT THE UPS OR ANY ASSOCIATED BATTERY BANKS USING ONLY THE FRONT PANEL MOUNTING EARS AS DAMAGE...

Page 7: ...voltage This will assure a close matching voltage in the event the UPS is placed on bypass b Dip switch 3 enables or disables the Green Mode function The UPS is shipped from the factory with the switc...

Page 8: ...battery fuse 8 If additional extended battery modules are to be installed perform the following a Perform the preperation outlined in preceding paragraphs 3a 3b abd 3c b Connect the supplied battery i...

Page 9: ...ollowed by the bypass LED and after several seconds the inverter LED 13 Turn on the connected equipment and verify the UPS does not go into overload by observing the front panel load indicator LEDs 14...

Page 10: ...for each module All 1kVA UPS models will only require one slide kit Slide Installation Instructions NOTE Only use the referenced lenght screws when mouning the slides to the sides of the UPS and batt...

Page 11: ...25 Min 300 Min RUN TIME 500W 24 Min 55 Min 95 Min 135 Min 180 Min RUN TIME 700W 17 Min 40 Min 70 Min 100 Min 140 Min RUN TIME 1000W 11 Min 25 Min 42 Min 60 Min 80 Min RUN TIME 1400W 7 Min 16 Min 26 Mi...

Page 12: ...the battery level is above the low battery warning Level The first LED is lit when the battery level is above the battery cutoff voltage 3 LINE SITE WIRING FAULT INDICATOR LED For models configured fo...

Page 13: ...s the different modes of operation for this button a Depressing this button when the UPS is off and the utility voltage is not present or with the UPS input circuit breaker in the off position will ca...

Page 14: ...rating range SG UPS OUTPUT VOLTAGE IS OUT OF PROPER RANGE b Four short beeps indicate the SG UPS output frequency is out of proper operating range The UPS must be repaired SG UPS OUTPUT FREQUENCY IS O...

Page 15: ...Fan RS 232 Port Output Receptacles 4 IEC320 Power Cord Inlet 200 240Vac only Output Voltage Select Switch Battery Fuse 30A Extended Battery Connector Primary Battery Inside UPS shown with cover plate...

Page 16: ...acles Primary Battery Connector shown with cover plate removed Cooling Fans RS 232 Port Output Receptacles 4 IEC320 Power Cord Inlet 200 240Vac only Output Voltage Select Switch Output Fuse Primary Ba...

Page 17: ...e propriatary pin out of the RS 232 port There are communications options that WILL DISABLE the RS 232 port and render it inoperable The options are as follows a Internal SNMP HTTP agent option instal...

Page 18: ...ommon only PIN JUMPER ASSIGNMENT FOR THE FALCON UA88374 RELAY OPTION BOARD no on bypass signal PIN JUMPER ASSIGNMENT FOR THE FALCON UA88376 RELAY OPTION BOARD with on bypass signal DB 9F PIN JUMPER AS...

Page 19: ...n for pins 2 3 5 5 Low Battery N O Closes at low battery 6 Remote Shutdown Applying a 5 12Vdc voltage level for 500ms while the UPS is on battery will shutdown the UPS 7 Not Used 8 Not Used 9 Not Used...

Page 20: ...see page 20 for contact information Never attempt to service batteries High voltage exists within the unit which could cause electrical shock Servicing of batteries should be performed or supervised...

Page 21: ...cause interference to radio and television reception All models covered in this manual have been tested and found to comply with the limits for a Class A computing device in accordance with the specif...

Page 22: ...d when returning any SG Series product Falcon Electric will not assume any responsibility for shipping damage In the event of shipping damage you will be notified of the damage and be instructed to fi...

Page 23: ...OF MERCHANTABILITY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND EXPRESS WARRANTIES THAT THIS PRODUCT WILL CONFORM TO ANY AFFIRMATION OR PROMISE FOR THIS PRODUCT AND THE USER AGREES THAT IN...

Page 24: ...oling Low Velocity Forced Air Fans Audible Noise 1 Meter 55dBA Controls and Indicators LED Line Inverter Battery Reserve Load Bypass Alarm Crest Battery Load Capacity Level Audible Alarms DC Mode Low...

Reviews: