background image

How To Use This Manual

This manual provides detailed instructions on maintenance,

lubrication, installation, and parts identification. Use the table

of contents below to locate required information.

Table of Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1

Lube Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1

Limited End Float. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1

Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 1-2

Installation & Alignment Instructions . . . . . . . . . . . . . Pages 2-4

Annual Maintenance, Relube & Disassembly . . . . . . . . . Page 4

Installation & Alignment Data . . . . . . . . . . . . . . . . . . . . Page 5

Parts Identification & Parts Interchangeability. . . . . . . . .  Page 6

CAREFULLY FOLLOW THE INSTRUCTIONS IN THIS

MANUAL FOR OPTIMUM PERFORMANCE AND TROUBLE

FREE SERVICE.

INTRODUCTION

This manual applies to Sizes 1150T thru 1260T and 150T thru

260T Falk SteelfIex Tapered Grid Couplings. Unless otherwise

stated, information for Sizes 1020T thru 1140T applies to Sizes

150T thru 260T respectively, e.g. 1150T = 150T, 1260T =

260T, etc. These couplings are designed to operate in either

the horizontal or vertical position without modification.
The performance and life of the couplings depend largely upon

how you install and service them. Carefully follow the

instructions in this manual for optimum performance and

trouble free service.

CAUTION:

Consult applicable local and national safety codes

for proper guarding of rotating members. Observe all safety

rules when installing or servicing couplings.

WARNING:

Lockout starting switch of prime mover and remove

all external loads from drive before installing or servicing

couplings.

LUBE FITTINGS

Cover halves have

3

/

8

NPT Iube holes. Use a standard grease

gun and Iube fitting as instructed on 

Page 4.

LIMITED END FLOAT

When electric motors, generators, engines, compressors and

other machines are fitted with sleeve or straight roller bearings,

limited axial end float kits are recommended for protecting the

bearings. Falk Steelflex couplings are easily modified to limit

end float; refer to 

Manual 428-820

 for instructions.

LUBRICATION

Adequate lubrication is essential for satisfactory operation.

Page 2

 provides a list of typical lubricants and specifications

for general purpose and long term greases. Because of its

superior lubricating characteristics and low centrifuge

properties, Falk Long Term Grease (LTG) is highly

recommended.
The use of general purpose grease requires re-lubrication of

the coupling at least annually.

Long Term Grease (LTG)

The high centrifugal forces encountered in couplings separate

the base oil and thickener of general purpose greases. Heavy

thickener, which has no lubrication qualities, accumulates

in the grid-groove area of Steelflex couplings resulting in

premature hub or grid failure unless periodic lubrication cycles

are maintained.
Falk Long Term Grease (LTG) was developed specifically for

couplings. It resists separation of the oil and thickener. The

consistency of Falk LTG changes with operating conditions. As

manufactured it is an NLGI #1/2 grade. Working of the

lubricant under actual service conditions causes it to become

semifluid while the grease near the seals will set to a heavier

grade, helping to prevent leakage.
LTG is highly resistant to separation, easily out performing all

other lubricants tested. The resistance to separation allows the

lubricant to be used for relatively long periods of time.
Steelflex couplings initially lubricated with LTG will not require

re-lubrication until the connected equipment is stopped for

servicing. If a coupling leaks grease, is exposed to extreme

temperatures, excessive moisture, or experiences frequent

reversals, more frequent lubrication may be required.
Although LTG grease is compatible with most other coupling

greases, the mixing of greases may dilute the benefits of LTG.

USDA Approval

LTG has the United States Department of Agriculture Food Safety

& Inspection Service approval for applications where there is no

possibility of contact with edible products. (H-2 ratings).

CAUTION:

Do not use LTG in bearings.

®

The Falk Corporation, P.O. Box 492, Zip 53201-0492

428-112

3001 W. Canal St., Zip 53208-4200, Milwaukee, WI USA Telephone: 414-342-3131

May 2000

Fax: 414-937-4359 e-mail: falkinfo@falkcorp.com web: www.falkcorp.com

Supersedes 12-98

Steelflex

®

Couplings

Installation and Maintenance

Type T10

Sizes 1150–1260 & 150–260

(Page 1 of 6)

TYPE T10 STEELFLEX COUPLING

Summary of Contents for Steelflex T10

Page 1: ... specifications for general purpose and long term greases Because of its superior lubricating characteristics and low centrifuge properties Falk Long Term Grease LTG is highly recommended The use of general purpose grease requires re lubrication of the coupling at least annually Long Term Grease LTG The high centrifugal forces encountered in couplings separate the base oil and thickener of general...

Page 2: ...C using an oven torch induction heater or an oil bath To prevent damage DO NOT heat hubs beyond a maximum temperature of 400 F 205 C When an oxy acetylene or blow torch is used use an excess acetylene mixture Mark hubs near the center of their length in several places on hub body with a temperature sensitive crayon 275 F 135 C melt temperature Direct flame towards hub bore using constant motion to...

Page 3: ...ss to the gap specified in Table 2 Page 5 Insert bar as shown above to same depth at 90 intervals and measure clearance between bar and hub face with feelers The difference in minimum and maximum measurements must not exceed the ANGULAR INSTALLATION limits specified in Table 2 3 Offset Alignment Align so that a straight edge rests squarely or within the limits specified in Table 2 on both hubs as ...

Page 4: ... tightening torques of all fasteners 3 Inspect seal ring and gasket to determine if replacement is required If leaking grease replace 4 When connected equipment is serviced disassemble the coupling and inspect for wear Replace worn parts Clean grease from coupling and repack with new grease Install coupling using new gasket as instructed in this manual Periodic Lubrication The required frequency o...

Page 5: ...nd Float CPLG SIZE Installation Limits Operating Limits Cover Fastener Tightening Torque Values Allow Speed rpm Lube Wt Parallel Offset P Angular x y Normal Gap 10 Parallel Offset P Angular x y End Float Physical Limit Min 2 x F Max In Max mm Max In Max mm In mm Max In Max mm Max In Max mm In mm lb in Nm lb kg 1150T 012 305 016 406 250 6 024 610 062 1 57 620 15 7 650 73 4 1500 4 3 1 95 1160T 012 3...

Page 6: ...may cause premature failure and personal or property damage from flying debris The Falk Corporation P O Box 492 Zip 53201 0492 428 112 3001 W Canal St Zip 53208 4200 Milwaukee WI USA Telephone 414 342 3131 May 2000 Fax 414 937 4359 e mail falkinfo falkcorp com web www falkcorp com Supersedes 12 98 Installation and Maintenance Steelflex Couplings Page 6 of 6 Sizes 1150 1260 150 260 Types T10 PART N...

Reviews: