background image

IMPORTANT!!!

ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS.
FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD BE FAMILIAR
WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT. ALL INDIVIDUALS WHO USE
THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THIS DEVICE.

Reusable Bolt Anchor

5,000

-lbf / 

22

kN

Model: FS881

V1.0

 

 

Part Number

Inspection:

Official periodic inspection must be made at least annually. The inspection must be 
performed by a qualified person other than the intended user. If severe weather or 
conditions exist then inspections must be carried out more frequently. All inspection 
results must be logged in the space provided above.

   1.

 Inspect unit for visible signs of damage or wear that could affect operation. For  

 

        example: kinked or frayed cables.

   2.

 Make sure all labeling is affixed to the unit.

   3. 

Check spoons and end termination operate smoothly with no metal burrs.

   4.

 When reusing a previously drilled hole, inspect for for debris or wallowing.

   5.

 Record inspection results in the space provide above.

 

*If any damage that could affect the strength or operation of the device, or 
unsafe conditions are found, proper disposal is required. The anchor connector 
must be rendered unusable and then properly discarded.

 

Comments

INSPECTION AND MAINTAINANCE LOG

MODEL NUMBER:

DATE OF MANUFACTURE:

Product Warranty, Limited Remedy and Limitation of Liability

WARRANTY: THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES 
OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED 
WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE.

  Equipment offered by FallSafe is 

warranted against factory defects in workmanship and materials for a 
period of one year from date of purchase. 

LIMITED REMEDY:

 Upon notice in writing, FallSafe will repair or replace 

all defective items at FallSafe’s sole discretion. FallSafe reserves the right 
to require that the defective item be returned to its plant for inspection 
before determining the appropriate course action. Warranty does not 
cover equipment damage resulting from wear, abuse, damage in transit, 
failure to maintain the product or other damage beyond the control of 
FallSafe.  FallSafe shall be the sole judge of product condition and 
warranty options.  This warranty applies only to original purchaser and is 
the only warranty applicable to this product. Please contact FallSafe 
technical service department  for assistance.

LIMITATION OF LIABILITY: IN NO EVENT WILL FALLSAFE BE LIABLE 
FOR ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL 
DAMAGES INCLUDING, BUT NOT LIMITED TO LOSS OF PROFITS, IN 
ANY WAY RELATED TO THE PRODUCTS REGARDLESS OF THE LEGAL 
THEORY ASSERTED.

Inspector Name

Read This Instruction Manual Carefully Before Using This Equipment.

User Instructions must always be available to the user and are not to be removed except by the user of this equipment. For proper use, see 
supervisor, User Instructions, or contact the manufacturer.

Compliant fall protection and emergency rescue systems help prevent serious injury during fall arrest.  Users and purchasers of this equip-
ment must read and understand the User Instructions provided for correct use and care of this product. All users of this equipment must 
understand the instructions, operation, limitations and consequences of improper use of this equipment and be properly trained prior to 
use per OSHA 29 CFR 1910.66 and 1926.503 or applicable local standards.  

Misuse or failure to follow warnings and instructions may result 

in serious personal injury or death. 

PURPOSE

The FS881 is an anchorage connector designed to function as an interface between the anchorage and a fall protection, work positioning, 
rope access, or rescue system for the purpose of coupling the system to the anchorage. Any references to “anchorage connector” in this 
manual include, and apply to, the FS881. 

USE INSTRUCTIONS

 

1.      Before using a personal fall arrest system, user must be trained in accordance with the requirements of OSHA 29 CFR  

 

                          1910.66 in the safe use of the system and its components.
 

2.      Use only with ANSI/OSHA compliant personal fall arrest or restraint systems. The anchorage must have the strength capable                   

 

          of supporting a static load, applied in the directions permitted by the system, of at least 5,000-lbf (22.2 kN) in the absence of  

                          certification.
 

3.      Use of this product must be approved by an Engineer or other qualified person to be compatible with any and all structural   

                           & operational characteristics of the selected installation location and system to be connected to this anchor. 

Improper use    

 

           may result in serious personal injury or death.

 

4.      The anchorage connector must be inspected prior to each use for wear, damage, and other deterioration. If defective 

 

 

                            

components are found the anchor connector must be immediately removed from service, in accordance with the 

 

          requirements of OSHA 29 CFR 1910.66 and 1926.502.

 

5.      The complete fall protection system must be planned (including all components, calculating fall clearance, and swing fall)    

 

           before using.

 

6.      A rescue plan, and the means at hand to implement it, must be in place that provides the prompt rescue of users in the  

 

 

          event of a fall, or assures that users are able to rescue themselves.

 

7.      After a fall occurs, anchorage connector must be removed from service and destroyed immediately.

USE LIMITATIONS

 

1.      The anchorage connector is designed for  a single user, with a capacity up to 310 lbs (140 kg) user including clothing, tools,   

 

          etc. 

 

2.      The anchorage connector may be pulled in any direction. 

 

3.      The anchorage connector is designed to be used in temperatures ranging from -40ºF to +130ºF (-40°C to +54°C).

 

4.      Do not expose the anchorage connector to chemicals or harsh solutions which may have a harmful effect.

 

5.      Do not alter or modify this product in anyway.

 

6.      Caution must be taken when using any component of a fall protection, work positioning, rope access, or rescue system near  

 

          moving machinery, electrical hazards, sharp edges, or abrasive surfaces, as contact may cause equipment failure, personal    

           

          injury, or death.

 

7.      Do not use/install equipment without proper training by a “competent person” as defined by OSHA 29 CFR 1926.32(f ).

 

8.      Do not remove the labeling from this product.

 

9.      Additional requirements and limitations may apply depending on anchorage type and fastening option utilized for  

 

 

          installation. All placements must be approved by an engineer or other qualified person. 

Improper use may result in serious  

 

            personal injury or death.

 

10.    "This anchorage connector should not be used as part of a horizontal lifeline system that has not been designed and or  

 

 

          approved to be used with 5,000-lbf anchorage connectors".

COMPATIBILITY LIMITATIONS

The anchorage connector must only be coupled to compatible connectors.  OSHA 29 CFR 1926.502 prohibits snaphooks from being 
engaged to certain objects unless two requirements are met: it must be a locking type snaphook, and it must be “designed for” making such 
a connection.  “Designed for” means that the manufacturer of the snaphook specifically designed the snaphook to be used to connect to 
the equipment listed.  The following connections must be avoided, because they can result in rollout* when a nonlocking snaphook is used:
 

• Direct connection of a snaphook to horizontal lifeline.

 

• Two (or more) snaphooks connected to one D-ring.

 

• Two snaphooks connected to each other.

 

• A snaphook connected back on its integral lanyard.

 

• A snaphook connected to a webbing loop or webbing lanyard.

 

• Improper dimensions of the D-ring, rebar, or other connection point in relation to the snaphook dimensions that would allow the  

 

   snaphook keeper to be depressed by a turning motion of the snaphook.

 

*Rollout: A process by which a snaphook or carabiner unintentionally disengages from another connector or object to which it is   

 

  coupled. (ANSI Z359.1-2007)

MAINTAINANCE, CLEANING AND STORAGE

Cleaning periodically will prolong the life and proper functioning of the product. The frequency of cleaning should be determined by 
inspection and by severity of the environment. Clean with compressed air and/or a stiff brush using plain water or a mild soap and water 
solution. Do not use any corrosive chemicals that could damage the product. Wipe all surfaces with a clean dry cloth and hang to dry, or use 
compressed air. When not in use, store anchorage connectors in a cool, dry, clean environment, out of direct sunlight and free of corrosive 
or other degrading elements.
 

WARNING

Fall Safe™

Zona Industrial da Varziela

Rua B Lote 54

4480-623 Vila do Conde

Portugal

+351 252 480 060 / www.fallsafe-online.com

Summary of Contents for FS881

Page 1: ...rength capable of supporting a static load applied in the directions permitted by the system of at least 5 000 lbf 22 2 kN in the absence of certification 3 Use of this product must be approved by an Engineer or other qualified person to be compatible with any and all structural operational characteristics of the selected installation location and system to be connected to this anchor Improper use...

Page 2: ... squeezing the trigger pull the anchor out of the hole 3 If the anchor becomes stuck insert a punch screwdriver or other object into the hole until it touches the top of the cleaning bushing 4 Lightly tap with a hammer making sure the tool is touching the top of the cleaning bushing while squeezing the trigger The cleaning bushing should be easily visible at the edge of the hole 5 If tool was requ...

Page 3: ...0 069 www fallsafe online com E mail support fallsafe online com Portugal EU WWW FALLSAFE ONLINE COM RFID QR CODE APK SN Ready for WWW FALLSAFE ONLINE COM VAROITUS INSTRUKSJONER KIINNITYSPISTE EN795 2012 B ANSI Z359 1 2007 LUE KAIKKI TIEDOT SISÄLTÖ KAKSI OHJEET YLEISET JA ERITYISET FS881 FS883 STD2018 REV 01 SUOMEN FS881 FS883 ...

Page 4: ...nnitystavan ja asennusvaihtoehdon mukaan Kaikki paikat on hyväksyttävä insinöörin tai muun pätevän henkilön toimesta Väärä käyttö voi johtaa vakavaan käyttöön henkilövahinko tai kuolema 10 Tätä kiinnityskytkintä ei saa käyttää osana horisontaalista pelastusjärjestelmää jota ei ole suunniteltu ja tai hyväksytty käytettäväksi 5 000 lbf n kiinnityspistokkeilla YHTEENSOPIVUUS RAJOITUKSET Ankkuriliitän...

Page 5: ... 252 480 069 www fallsafe online com E mail support fallsafe online com Portugal EU WWW FALLSAFE ONLINE COM RFID QR CODE APK SN Ready for WWW FALLSAFE ONLINE COM ADVARSEL INSTRUKSJONER ANKER EN795 2012 B ANSI Z359 1 2007 LES ALLE INFORMASJON INNHOLD TO RETNINGSLINJER GENERELT OG SPESIELT FS881 FS883 STD2018 REV 01 NORSK ...

Page 6: ... godkjent av en ingeniør eller annen kvalifisert person Feil bruk kan føre til alvorlig bruk personskade eller død 10 Denne forankringskoblingen skal ikke brukes som en del av et horisontalt livlinjesystem som ikke er konstruert og eller godkjent for bruk med 5 000 lbf forankringskoblinger KOMPATIBILITETSBEGRENSNINGER Forankringskoblingen må kun kobles til kompatible kontakter OSHA 29 CFR 1926 502...

Page 7: ...1 252 480 069 www fallsafe online com E mail support fallsafe online com Portugal EU WWW FALLSAFE ONLINE COM RFID QR CODE APK SN Ready for WWW FALLSAFE ONLINE COM ADVARSEL VEJLEDNING ANKER EN795 2012 B ANSI Z359 1 2007 LES ALLE INFORMASJON INNHOLD TO RETNINGSLINJER GENERELT OG SPESIELT FS881 FS883 STD2018 REV 01 DANISH ...

Page 8: ...ficeret person Forkert brug kan føre til alvorlig brug personskade eller død 10 Denne dockingskobling må ikke anvendes som led i et horisontalt livlængdesystem der ikke er konstrueret og eller godkendt til brug med 5 000 lbf forankringskoblinger FORENELIGHED BEGRÆNSNINGER Dockingstilslutningen må kun tilsluttes kompatible stik OSHA 29 CFR 1926 502 forbyder snafooks at blive forlovet med bestemte g...

Reviews: