background image

29

 

 

Nunca,

 

bajo

 

ninguna

 

circunstancia,

 

la

 

SRL

 

debe

 

conectarse

 

al

 

anillo

 

en

 

"D"

 

lateral

 

o

 

de

 

la

 

cadera:

  

este

 

tipo

 

de

 

conexión

 

podría

 

causar

 

lesiones

 

graves

 

o

 

la

 

muerte.

  

Asegúrese

 

de

 

leer

 

y

 

seguir

 

las

 

instrucciones

 

del

 

fabricante

 

incluidas

 

con

 

el

 

arnés

 

de

 

cuerpo

 

completo

 

en

 

el

 

momento

 

de

 

la

 

compra.

  

2.3:

  

Conectores/dispositivos

 

de

 

conexión

 

     

Los

 

conectores

 

y

 

dispositivos

 

de

 

conexión

 

son

 

términos

 

que

 

a

 

veces

 

se

 

utilizan

 

indistintamente.

  

Es

 

importante

 

destacar

 

las

 

diferencias

 

entre

 

estos

 

dos

 

términos

 

con

 

el

 

fin

 

de

 

ayudar

 

a

 

distinguir

 

el

 

papel

 

que

 

estos

 

componentes

 

tienen

 

en

 

el

 

montaje

 

de

 

su

 

PFAS.

  

En

 

ambos

 

casos,

 

estos

 

productos/componentes

 

son

 

necesarios

 

para

 

tener

 

una

 

mínima

 

resistencia

 

estática

 

de

 

5.000

 

libras

 

(2.268

 

kg).

  

Para

 

obtener

 

información

 

adicional

 

sobre

 

los

 

requisitos

 

para

 

los

 

conectores

 

y

 

dispositivos

 

de

 

conexión,

 

consulte

 

la

 

norma

 

1926.502

 

de

 

la

 

OSHA

 

en

 

www.osha.gov

 

según

 

se

 

indica

 

en

 

la

 

Sección

 

1

 

del

 

Aviso

 

No.

 

1.

 

     

Un

 

conector

 

es

 

un

 

elemento

 

metálico

 

mecánico

 

tal

 

como

 

un

 

mosquetón,

 

gancho

 

de

 

cierre

 

instantáneo

 

o

 

gancho

 

de

 

refuerzo

 

que

 

conecta

 

físicamente

 

uno

 

o

 

más

 

elementos

 

de

 

su

 

PFAS

 

de

 

una

 

manera

 

que

 

continúen

 

conectados

 

entre

 

sí,

 

a

 

menos

 

que

 

sean

 

desconectados

 

intencionalmente.

  

     

Un

 

dispositivo

 

de

 

conexión

 

es

 

un

 

elemento

 

que

 

conecta

 

su

 

arnés

 

de

 

cuerpo

 

completo

 

al

 

anclaje

 

en

 

un

 

esfuerzo

 

por

 

asegurarse

 

de

 

que

 

usted

 

permanezca

 

conectado

 

o

 

amarrado

 

a

 

la

 

estructura

 

en

 

la

 

cual

 

trabaja.

   

En

 

otras

 

palabras,

 

el

 

dispositivo

 

de

 

conexión

 

es

 

el

 

elemento

 

que

 

lo

 

asegura

 

a

 

su

 

sistema

 

de

 

anclaje.

 

2.4:

  

Dispositivos

 

de

 

desaceleración

 

     

Un

 

dispositivo

 

de

 

desaceleración

 

es

 

el

 

elemento

 

de

 

un

 

Sistema

 

personal

 

de

 

detención

 

de

 

caídas

 

(PFAS,

 

por

 

sus

 

siglas

 

en

 

inglés)

 

que

 

se

 

activa

 

durante

 

un

 

evento

 

de

 

caída

 

y

 

reduce

 

las

 

fuerzas

 

ejercidas

 

sobre

 

el

 

cuerpo

 

del

 

usuario

 

y

 

en

 

el

 

anclaje

 

durante

 

la

 

detención

 

de

 

la

 

caída.

   

En

 

el

 

caso

 

de

 

su

 

SRL

 

de

 

red

 

de

 

FallTech

,

 

este

 

producto

 

es

 

un

 

dispositivo

 

de

 

conexión

 

y

 

de

 

desaceleración,

 

pues

 

lo

 

mantendrá

 

conectado

 

a

 

su

 

anclaje

 

y

 

reducirá

 

las

 

fuerzas

 

sobre

 

su

 

cuerpo

 

en

 

caso

 

de

 

una

 

caída.

  

Para

 

obtener

 

más

 

información

 

sobre

 

la

 

capacidad

 

y

 

las

 

especificaciones

 

de

 

su

 

SRL

 

red

 

de

 

FallTech

,

 

consulte

 

la

 

sección

 

10

 

de

 

este

 

manual

 

de

 

instrucciones.

  

2.5:

  

Detención

 

de

 

caídas

 

     

La

 

Detención

 

de

 

caídas

 

es

 

un

 

área

 

de

 

la

 

protección

 

contra

 

caídas

 

que

 

se

 

enfoca

 

en

 

detener

 

una

 

caída

 

una

 

vez

 

que

 

ha

 

ocurrido.

   

Los

 

Sistemas

 

personales

 

de

 

detención

 

de

 

caídas

 

normalmente

 

consisten

 

en

 

un

 

anclaje,

 

un

 

arnés

 

de

 

cuerpo

 

completo

 

y

 

una

 

cuerda

 

de

 

salvamento

 

auto

retráctil,

 

un

 

cordón

 

con

 

amortiguación

 

u

 

otro

 

dispositivo

 

de

 

desaceleración

 

diseñado

 

para

 

detener

 

a

 

un

 

usuario

 

en

 

caída

 

en

 

la

 

distancia

 

más

 

corta

 

posible

 

mientras

 

que

 

limita

 

la

 

fuerza

 

ejercida

 

en

 

el

 

cuerpo

 

del

 

usuario.

 

2.6:

  

Restricción

 

contra

 

caídas

 

     

La

 

Restricción

 

contra

 

caídas

 

es

 

un

 

área

 

de

 

protección

 

contra

 

caídas

 

dedicada

 

a

 

restringir

 

al

 

usuario

 

del

 

sistema

 

de

 

una

 

manera

 

que

 

restrinja

 

su

 

acceso

 

al

 

peligro

 

de

 

caída

 

en

 

una

 

forma

 

que

 

no

 

pueda

 

ser

 

objeto

 

de

 

una

 

caída.

   

Un

 

típico

 

Sistema

 

de

 

restricción

 

contra

 

caídas

 

consta

 

de

 

un

 

anclaje,

 

un

 

arnés

 

de

 

cuerpo

 

completo

 

o

 

una

 

correa

 

de

 

restricción

 

y

 

un

 

cordón

 

de

 

sujeción.

  

Nunca

 

se

 

debe

 

utilizar

 

un

 

sistema

 

SRL

 

en

 

una

 

aplicación

 

de

 

restricción,

 

ya

 

que

 

no

 

es

 

capaz

 

de

 

restringir

 

el

 

acceso

 

del

 

usuario

 

a

 

los

 

peligros

 

de

 

caídas.

  

2.7:

  

Posicionamiento

 

del

 

trabajo

 

     

El

 

Posicionamiento

 

del

 

trabajo

 

es

 

un

 

área

 

de

 

protección

 

contra

 

caídas

 

dedicada

 

a

 

permitir

 

que

 

el

 

usuario

 

trabaje

 

sobre

 

una

 

superficie

 

vertical

 

a

 

través

 

de

 

un

 

ensamblaje

 

de

 

posicionamiento,

 

y

 

restringe

 

la

 

exposición

 

del

 

usuario

 

a

 

una

 

caída

 

de

 

no

 

más

 

de

 

dos

 

pies

 

(0,6

 

m).

   

Los

 

ensamblajes

 

típicos

 

de

 

posicionamiento

 

consisten

 

en

 

un

 

gancho

 

de

 

refuerzo

 

grande

 

y

 

una

 

longitud

 

de

 

cadena,

 

cuerda,

 

cable

 

o

 

correa

 

con

 

un

 

gancho

 

doble

 

de

 

cierre

 

instantáneo

 

en

 

cualquiera

 

de

 

los

 

extremos.

  

Estos

 

ganchos

 

de

 

cierre

 

instantáneo

 

se

 

conectan

 

a

 

los

 

anillos

 

en

 

"D"

 

en

 

las

 

caderas

 

o

 

en

 

la

 

cintura

 

del

 

arnés

 

de

 

cuerpo

 

completo

 

del

 

usuario,

 

con

 

el

 

gancho

 

de

 

refuerzo

 

conectado

 

a

 

la

 

estructura

 

en

 

la

 

Summary of Contents for 7262

Page 1: ...LURE TO UNDERSTAND AND COMPLY WITH THESE INSTRUCTIONS CAN RESULT IN SERIOUS INJURY OR DEATH IF THESE INSTRUCTIONS ARE UNCLEAR TO YOU PLEASE CONSULT A COMPETENT PERSON SHOULD THESE INSTRUCTIONS BECOME...

Page 2: ...Steel 310 lbs N 8262 8 Web Retractor Polyester Alloy Steel 3 600 lb Gates 310 lbs Y 7276WR 20 Web SRL Dyneema Alloy Steel 3 600 lb Gates 310 lbs Y 7271WR 15 Web SRL Polyester Alloy Steel 3 600 lb Gate...

Page 3: ...ons and Qualified Persons ANSI Z359 0 2007 goes on to further define the roles and qualifications of these individuals as well as Authorized Persons and their importance in the workplace These terms a...

Page 4: ...the line to retract SLOWLY back into housing Do make compatible connections see Advisory 3 at the end of this Section Do use a tagline if the SRL is remotely mounted to access cable and control the re...

Page 5: ...hat the rings or structural members to which they are attached will not pose a risk of forcing the gate open and must fully captivate the connector so that it cannot become disengaged slide or shift d...

Page 6: ...ched to a side or hip d ring Such a connection could cause serious injury or death Be sure to read and follow the manufacturer s instructions included with your full body harness at the time of purcha...

Page 7: ...ce of 6 6 feet when rigging a Personal Fall Arrest System PFAS In some cases exceptions may be allowed when there is no practical way to limit the Free Fall Distance to 6 such as a job site where no o...

Page 8: ...iagram 2 10 Swing Fall Swing Fall is the phenomenon that occurs when the user falls from a location that is not directly adjacent to or directly below the anchorage connector This is also referred to...

Page 9: ...y out and retract automatically In the event of a fall a centrifugal brake will arrest the fall in a very short distance while greatly reducing the forces associated with the arrest Before using this...

Page 10: ...bove the walking working surface and allows for a maximum Free Fall Distance of 2 feet Horizontal Lifelines This product is suitable for use in any application where a horizontal lifeline has been ins...

Page 11: ...re proper deceleration in the event of a fall 2 Read understand and comply with manufacturer s instructions for each component of your Personal Fall Arrest System Full Body Harness Anchorage Connector...

Page 12: ...rs of fall arrest products The ANSI standard recommends the following steps be taken A workplace assessment by a competent person taking into account the presence of sources of extreme heat chemicals...

Page 13: ...e absence of certification If multiple personal fall arrest systems are being attached to the same anchorage the minimum values stated above must be multiplied by the number of users Ensure that the a...

Page 14: ...ilities of designated persons Authorized Competent Qualified How to use written fall protection procedures Inspection of equipment components and systems before use Fall protection rescue procedures I...

Page 15: ...s This condition can result in a variety of symptoms some of which include light headedness loss of consciousness difficulty concentrating and palpitations Following a rescue Suspension Trauma can be...

Page 16: ...urring If these conditions exist and are beginning to cause damage to the webbing remove the SRL from service 6 Inspect the carabiner snap hook gates at the anchorage and attachment ends of the produc...

Page 17: ...Use a damp rag to clean the surfaces of any connecting hardware 4 If there is an excessive build up of paint oil dirt tar or other contaminants that cannot be removed remove the SRL from service and...

Page 18: ...Steel 5 000 lbs Overall static strength 3 000 lbs Arrest Forces 900 lbs Deceleration Distance 24 Maximum Capacity 310 lbs When tested in accordance with ANSI Z359 1 2007 FallTech Web SRL s Model s 727...

Page 19: ...teel 5 000 lbs Overall static strength 3 000 lbs Arrest Forces 900 lbs Deceleration Distance 24 Maximum Capacity 310 lbs When tested in accordance with ANSI Z359 1 2007 10 3 Labels and Markings The la...

Page 20: ...20 Fig 10 2 Product label for FallTech Web SRL s 7270WR 7271WR and 7270KV Located on front housing Fig 10 3 Warning label for FallTech Web SRL s 7270WR 7271WR and 7270KV Located on rear housing...

Page 21: ...21 Fig 10 4 Product label for FallTech Contractor Web SRL 7276WR Located on front housing Fig 10 5 Product labels for FallTech Contractor Web SRL 7276WR Located on rear housing...

Page 22: ...heck with your State Department of Labor for further details ANSI standards are available for purchase through the e standards store at www ansi org ANSI Z359 1 2007 Safety Requirements for Personal F...

Page 23: ...L ES PARTE ESTE PRODUCTO NO COMPRENDER NI CUMPLIR CON ESTAS INSTRUCCIONES PUEDE OCASIONAR LESIONES GRAVES O LA MUERTE SI ESTAS INSTRUCCIONES NO EST N CLARAS PARA USTED CONSULTE A UNA PERSONA COMPETENT...

Page 24: ...0 libras 1 633 kg Compuertas 310 libras 140 6 kg Y 7276WR SRL de red de 20 pies 6 1 m Dyneema Aleaci n de acero 3 600 libras 1 633 kg Compuertas 310 libras 140 6 kg Y 7271WR SRL de red de 15 pies 4 6...

Page 25: ...secci n para obtener m s detalles No utilizar componentes compatibles puede resultar en una falla del sistema para funcionar seg n lo previsto lo cual puede provocar lesiones graves o la muerte En los...

Page 26: ...los peligros del ca da con balanceo ver Secci n 2 9 S inspeccione toda la cuerda de salvamento de la SRL para detectar cortes abrasiones torceduras desgaste u otros da os S inspeccione el gancho con...

Page 27: ...Aviso No 1 Lectura adicional Si tiene acceso a Internet visite www osha gov Este sitio web es un recurso excepcional y tiene una gran cantidad de informaci n de f cil acceso Utilice el campo de b squ...

Page 28: ...nci n de ca das PFAS por sus siglas en ingl s La OSHA 1926 502 d 15 dispone lo siguiente Los anclajes utilizados para conectar los equipos personales de detenci n de ca das deber n ser independientes...

Page 29: ...n dispositivo de conexi n y de desaceleraci n pues lo mantendr conectado a su anclaje y reducir las fuerzas sobre su cuerpo en caso de una ca da Para obtener m s informaci n sobre la capacidad y las e...

Page 30: ...capaces de detener la ca da del usuario antes de que llegue al siguiente nivel inferior La distancia de ca da despejada requerida se puede calcular f cilmente al sumar la distancia de ca da libre la...

Page 31: ...e el usuario no s lo cae verticalmente sino que tambi n se balancea horizontalmente Esto puede ocasionar peligros adicionales por ejemplo puede balancearse hacia una obstrucci n o elemento estructural...

Page 32: ...etraer autom ticamente En el caso de una ca da un freno centr fugo detendr la ca da en una distancia muy corta mientras reduce en gran medida las fuerzas asociadas con la detenci n Antes de utilizar e...

Page 33: ...su sistema personal de detenci n de ca das lo cual puede resultar en lesiones graves o la muerte Aplicaciones directas por encima del nivel de la cabeza Este producto es apto para su uso en cualquier...

Page 34: ...n reas donde la cuerda de salvamento pueda entrar en contacto con temperaturas elevadas o escoria de soldadura FallTech recomienda el uso de la SRL con tramado de aramida Kevlar Nomex o Dyneema para e...

Page 35: ...s de ca das con balanceo cuando trabaje en ngulos extremos Una vez que se han tomado las medidas anteriores el usuario tendr acceso a su rea de trabajo mientras camina y se mueve a velocidades normale...

Page 36: ...egurar de leer y seguir las instrucciones marcas y advertencias del fabricante Si el PFAS que se selecciona posee componentes de diferentes fabricantes la persona competente se asegurar de que estos c...

Page 37: ...del producto equipos Si est obligado a proporcionar equipos de protecci n contra ca das para sus empleados aseg rese de consultar o nombrar a una persona competente o calificada para seleccionar y pre...

Page 38: ...ir barandillas redes cubiertas etc Los productos de detenci n de ca das son la ltima l nea de defensa en la jerarqu a de protecci n contra ca das y deben utilizarse como ltimo recurso por parte de los...

Page 39: ...sta afecci n puede resultar en una variedad de s ntomas entre los cuales se incluyen mareo p rdida de la conciencia dificultad para concentrarse y palpitaciones Despu s de un rescate el trauma por sus...

Page 40: ...te excesivo bordes cortantes o rebabas Si existen estas condiciones y est n empezando a da ar la cuerda retire la SRL de servicio 6 Inspeccione las compuertas del mosquet n gancho de conexi n en el an...

Page 41: ...es Aseg rese de que las etiquetas son legibles en todo momento 2 Utilice un trapo h medo y jab n suave y agua para limpiar la red de la SRL D jela secar 3 Utilice un trapo h medo para limpiar las supe...

Page 42: ...lificaci n Cubierta Aleaci n de acero 3 600 libras 1 633 kg Tambor Pl stico ABS n a Eje principal Aleaci n de acero 3 400 libras 1 542 2 kg Trinquetes Aleaci n de acero n a Red Poli ster 5 000 libras...

Page 43: ...iles SRL con red de la serie Contractor de FallTech No de modelo 7276WR Componente Material Calificaci n Cubierta Nil n 6 6 en aleaci n de acero 3 000 libras 1 360 8 kg Tambor Aluminio n a Eje princip...

Page 44: ...s para el Retractor de red de FallTech 7262 72624 7263 y 8262 Situadas en la cuerda encima del gancho Fig 10 2 Etiqueta del producto para las SRL de red de FallTech 7270WR 7271WR y 7270KV Situada en l...

Page 45: ...270KV Situada en la cubierta trasera Fig 10 4 Etiqueta del producto para la SRL de red de la serie Contractor de FallTech 7276WR Situada en la cubierta delantera Fig 10 5 Etiquetas del producto para l...