background image

Concrete Hollow Core Mount 

  Drill a ¾ in. diameter hole in the center of the core hollow. 

  Never drill the hole closer than 6” to any edge or corner. Use a rotary hammer 

drill and industrial grade SDS bit. Do not use a masonry bit. 

  If using a previously drilled hole always inspect the hole carefully to ensure there 

are no loose, deformed, or crumbling edges. 

  Ensure the toggle bar is placed in the hole in the insert position. See Figure 3. 

  The deployed position of the Toggle Bar is at right angles to the main cable. 

Grasp the anchor loop in one hand, and with the other, turn the toggle bar so it 
points straight out, in line with the main cable. When the machined flat on the end 
of the  toggle bar engages the flat on the bottom of the hole plug, the Toggle Bar 
with remain in the insert position. See Figure 3.  

Insert the Toggle Bar end into the drilled hole. Push the loop as far as it will go to 
fully compress the spring. Ensure the hole plug engages the hole. Let the spring 
expand. The Toggle Bar will rotate into the deployed position. Ensure the 
centerline of the Toggle Bar is in line with the centerline of the hollow core. Do 
not allow the Toggle Bar to cross the axis of the hollow core centerline 

 

 

 

 

Figure 3 – ToggleLok With Toggle Bar in Insert  Position and Deployed Position 

 

 

 

Toggle Bar 

in Insert 
Position 

Toggle Bar in 

Insert  Position 

Toggle Bar in 

Deployed Position 

Summary of Contents for 7442

Page 1: ...peration Instruction Manual Toggle Lok Anchor Model 7442 Portable Concrete Anchorage Connector ANSI Z359 1 5 000 lbs 22 24 kN FallTech Inc 1306 Alameda Street Compton CA 90221 800 719 4619 323 752 006...

Page 2: ...losed and locked Connector strength must meet the 5 000 lb requirements All personal fall arrest systems must meet all applicable state federal city OSHA and ANSI requirements and any other regulating...

Page 3: ...ial The Toggle Lok anchor may be mounted on horizontal surfaces vertical surfaces and overhead ceiling surfaces If a previously drilled hole is to be used inspect it carefully and ensure it is of the...

Page 4: ...num Trigger Assembly Capacity 130 400 lbs 59 181 kg Lot 120814 Make only compatible connections Avoid contact with harsh chemicals excessive heat and high voltage Do not use in wet or uncured concrete...

Page 5: ...Copper Return Wire 1x19 Aircraft Cable INSTALLATION LOCATION Choose the mounting location carefully Free fall distance shall be limited to 6 feet Always calculate the fall distance and ensure that a c...

Page 6: ...The unit is straight and operates smoothly The label is affixed to the unit The cable is not kinked frayed or damaged The metal components are not damaged The Toggle Bar operates freely MOUNT THE TOG...

Page 7: ...so it points straight out in line with the main cable When the machined flat on the end of the toggle bar engages the flat on the bottom of the hole plug the Toggle Bar with remain in the insert posi...

Page 8: ...n ensure the center of the drilled hole is at least 1 in from the edge of the beam See Figure 4 for acceptable mounting orientations Do not exceed 90 degree bends Figure 5 depicts an unacceptable orie...

Page 9: ...INSTALLATION INSPECTION Once installation of the ToggleLok anchor is complete ensure the following before use the permanent label is affixed to unit cable is not kinked frayed or damaged metal compone...

Page 10: ...ce it where it can be stepped on Keep the unit free of grease dirt and oil Do not lend the unit to others DISPOSAL If a fall arrest event has occurred or if inspection has revealed a fault or unsafe c...

Reviews: