4.6
Leveling
When using the Confined Space Davit System, the base must be level at all times with the legs pinned and tightened in place.
To level of the davit, adjust each leg height until the bubble is centered in the bubble level, see Figure 26.
4.7
Fine Offset Adjustment
The Confined Space Davit System is equipped with a fine adjustment screw to help ensure the anchor point is centered over the
entry/egress location. To adjust, turn the fine adjustment screw to raise and lower the arm to the desired position, see Figure 27.
Figure 26
Figure 27
4.8
Winch/3-Way Installation
Based on your application, attach the FallTech Davit Device Receiver Bracket to the davit using the provided detent pins. See Figure 28 for
correct and Figure 29 for incorrect orientations of the Davit Receiver Bracket. DO NOT mount any device on the front of the lower mast.
Figure 28 - Correct Device Bracket Mounting
Figure 29 - Incorrect Device Bracket Mounting