5.0 Maintenance, Service, and Storage
Maintenance:
No scheduled maintenance is required, other than the replacement of items that failed inspection.
Service:
There are no specific service requirements for this system component.
Storage:
If the unit is removed from its installation location, it should be stored in a dry area free of corrosive elements that may harm
or cause the product not to function.
6.0 Inspection
6.1
Pre-Use Inspection:
6.1.1
Inspect the additional equipment used on the davit arm per the user instruction manual for the specific equipment. Do not use
if the equipment fails inspection.
6.1.2
Inspect the Confined Space Davit System thoroughly for damage. Inspection should include checking the structure for dents,
cracks, deformed, or bent tubing.
6.1.3
Inspect all hardware for damage, wear, or missing parts.
6.1.4
Check all rollers and pulleys for to ensure proper movement. Check for damage such as cracks, chips, and excessive wear.
6.1.5
Ensure all detent pins are properly secured before every use.
Do not use the FallTech Confined Space Davit or additional equipment if it fails any part of this inspection.
6.2
Inspection Frequency:
Pre-Use: Inspect the Confined Space Davit System and additional equipment weekly as outlined in section 6.1. All installations must be
approved to local standards by a Qualified Person.
Annually: The Confined Space Davit System and additional equipment must be inspected by a Qualified Person annually and recorded on
the Inspection Record provided or equivalent document.