background image

 
 

 

 

 

For test of the alarm receiver program: 

From keypad:  

 

From phone:  

 800 #

 

Note: If the main alarm was never acknowledged, no Info Alarm will be sent out. Also, this 
function will not dial out an Info Alarm following battery alarms nor test alarms/routine calls or 
end-of-alarm. 

 

End-of-alarm 

To ensure that a trapped passenger is actually released from the lift there is a function which 
sends an end-of-alarm call with a specific alarm type to the alarm receiver. Alarm type is default 
28. 

This alarm is activated by the rescue service by pressing a magnet to the front of the ECII™ 
Flex after having released the trapped person. See drawing below for location of the magnetic 
switch. This is default deactivated. For activation or changing then alarm type:  

For activation of magnetic switch: 

From keypad:   

 

From phone:  

 620 # 

From keypad:  

 

From phone:  

# 620 #

 

For activation of magnetic switch and setting a different alarm type: 

From keypad:   

 

 < alarm type > 

 

From phone:  

 620 

 < alarm type > # 

It is also possible to specify that the magnetic switch should only be active for 6 hours after an 
emergency alarm. This function is activated using: 

From keypad:   

 

From phone:  

 621 # 

The 6 hour open magnetic switch will use the default alarm type specified for the magnetic 
switch function. To program another alarm type for the 6 hour open magnetic switch, first use: 

From keypad:   

 

 < alarm type > 

 

From phone:  

 620 

 < alarm type > # 

Then activate the 6 hour open magnetic switch by programming: 

From keypad:   

 

From phone:  

 621 # 

The 6 hour open magnetic switch can be deactivated and alarm type reset, the magnetic switch 
will be turned off, use: 

From keypad:   

 

From phone:  

# 621 # 

It is also possible to send an end-of-alarm using the keypad or a telephone. The call will be 
made after leaving programming mode. The alarm can be sent using: 

162187 Manual FältCom ECII™ Flex 

Page 29 of 40

 

 

Summary of Contents for ECII Flex

Page 1: ...Version 3 2 4 B Updated 2014 08 28 F ltCom ECII Flex Manual...

Page 2: ...162187 Manual F ltCom ECII Flex Page 2 of 40...

Page 3: ...Flat cable type 12 5 4 4 Connection via existing cable 12 Connection of voltage supply 12 Connection to loop amplifier 13 Connection of external pictogram 13 Connection to Intercom art 102153 01 13 C...

Page 4: ...25 Acknowledge on end 323 26 Detection of busy alarm receiver 26 LED flashing sequence 27 Programmable alarm types 27 Info Alarm logging of alarms 28 End of alarm 29 6 22 1 End of alarm receiver 30 Al...

Page 5: ...ght proprietor Copyright 2008 2013 3 Declaration of Conformity We F lt Communications AB Vasagatan 23 S 90329 Ume Sweden hereby declare that this product F ltCom ECII Flex 202187 conforms with the dir...

Page 6: ...one all the electronics the keys for programming and testing as well as all connection points are integrated in one single unit This gives quick and easy installation as well high reliability in opera...

Page 7: ...ry mounting parts Multiple ECII Flex connection The F ltCom ECII Flex is designed to run on the existing telephone line power supply Sep arate power supply is only required if several lift phones are...

Page 8: ...ys This alarm tests the lift phone electron ics and the telephone line itself There is one primary and one secondary test receiver availa ble The ECII Flex will answer an incoming call automatically a...

Page 9: ...fficient installation Mind your own safety when installing ECII Flex You must never work in an open lift shaft without a safety harness Be extremely careful and break current if you work close to a vo...

Page 10: ...on must be replaced with another type or use a relay to isolate the connectors Please note that the ECII Flex has a special version called ALBU with an integrated alarm button which can be used if the...

Page 11: ...II Flex with a the lift phone accepts that the telephone line manages to call up the pre programmed number Afterwards the ECII Flex uses the telephone line for the intended functions For more informat...

Page 12: ...d for the ECII Flex It is important that the wires to be used are next to each other in the lift cable in order to minimize disturbances In the event of bad sound quality a separate cable must be used...

Page 13: ...oom and connect the power and telephone line Connect the ECII Flex in the lift car to the LIFT CAR output on the Intercom Unit Please view the Intercom installation instruction for more information Co...

Page 14: ...or alarm receiver 2 The other keys have the same function as on a standard telephone Configuration settings The ECII Flex can be programmed only after it has been set to programming mode The telephone...

Page 15: ...ne is heard enter the phone number to call out to a phone or press to start programming the unit 6 2 4 Reprogramming from phone Call the telephone number to which the ECII Flex is connected and wait f...

Page 16: ...correct alarm receiver number If the alarm receiver is a standard telephone or a mobile choose your own alarm code There must always be an alarm code programmed in order for the ECII Flex to call the...

Page 17: ...phone 0 Telephone number max 20 digits 6 6 2 Prefix in a PABX switch board If the ECII Flex is connected to a PABX that requires a prefix to get an external extension program a star after the prefix E...

Page 18: ...Reset to normally closed alarm button From keypad From phone 020 Note If alarm input 1 is filtered there is a 30 second override meaning if the alarm button is pushed more than 30 seconds an emergency...

Page 19: ...activated with From keypad From phone 022 Please view document Flex I O description for information on what pins to use Test of alarm reception After a finished installation F ltCom highly recommends...

Page 20: ...Flex and the alarm receiver Automatic test alarm routine call shall only be pro grammed if the ECII Flex is connected to an alarm central the alarm central can verify that the incoming test alarms rou...

Page 21: ...l after main alarm 1 b Select the required test interval 1 to 30 days Use a number between 1 and 30 From keypad Days 1 30 From phone 082 1 30 If the test alarm routine call should go to the same recei...

Page 22: ...pad From phone 302 Incoming calls It is possible to call the ECII Flex and talk to the trapped person If there is only one ECII Flex on the line the unit can be set to answer immediately without selec...

Page 23: ...he ECII Flex 6 12 2 Single unit on the line If the ECII Flex does not share the line with any other equipment the unit can be set to answer the call without requiring the selection of the number on th...

Page 24: ...ne 310 telephone number Enter Alarm code default Alarm Code 1 From keypad Alarm code max 10 digits From phone 311 Alarm code max 10 digits Deactivate function From keypad From phone 310 Test of the al...

Page 25: ...cknowledge the alarm and the button disconnects the alarm call Each time any of the buttons 0 9 is pressed on the telephone the disconnect time out is reset to 180 seconds Only duplex mode is availabl...

Page 26: ...alarm call The can be changed to any tone for disconnecting the call use this if there are other brands of emergency phones that require a different disconnect command The function is activated with...

Page 27: ...lashing sequence by programming From keypad From phone 510 Programmable alarm types When sending an alarm to an alarm receiver using the CPC protocol the ECII Flex will be identified by the alarm code...

Page 28: ...t alarm after an emergency alarm using the alarm type 89d 59h This alarm can be used to access a log in an alarm receiver if the lift call has been sent to a regular telephone The Info alarm will use...

Page 29: ...ne 620 From keypad From phone 620 For activation of magnetic switch and setting a different alarm type From keypad alarm type From phone 620 alarm type It is also possible to specify that the magnetic...

Page 30: ...If no End of alarm code is specified the ECII Flex will use the Alarm code 1 Alarm protocol The CPC protocol is the default protocol used in ECII Flex An alternative protocol P100 is also available Th...

Page 31: ...tone in order to initiate the call Dial tone detection is activated with From keypad From phone 040 To deactivate the dial tone detection From keypad From phone 040 Speech messages It is possible to r...

Page 32: ...ng of message 2 From keypad wait for tone read message Max 16 seconds From phone 420 wait for tone read message Max 16 seconds Listening to message 2 From keypad From phone 420 Deleting message 2 From...

Page 33: ...on call is then set up as in a normal telephone call A call will be disconnected automatically three minutes after the last key pressing i e three minutes after the call is acknowledged With thirty se...

Page 34: ...ve alarm mode it is possible make a call to the ECII Flex from a tone dialling phone or a mobile phone according to the following 1 Dial the number to the lift phone 2 After one ring signal the first...

Page 35: ...me control is turned The new volume will be used in all following calls Please note that previous versions of the ECII Flex have a different procedure for the volume control To change the volume durin...

Page 36: ...x COP Part No 2187 Rev z z Snr MCCCCC W yyww www faltcom se The box label describes same information as above but has additionally the barcode EAN 128 indicating XXXXZZYYWWCCCCC XXXX Part number ZZ Ha...

Page 37: ...ons The company is not obliged to make immediate updates to reference manuals 10 Updates Visit our web site to access the latest updates regarding market information and technical doc umentation http...

Page 38: ...Service form 162187 Manual F ltCom ECII Flex Page 38 of 40...

Page 39: ...ication when programming Test alarm routine call 1 time day up to once every 30 days selectable on off Alarm receiver types Contact your local distributor for information about alarm cen tres that can...

Page 40: ...6 0 90 18 39 27 E mail support liftphones faltcom se Phone 46 0 90 18 39 00 exchange Fax 46 0 90 18 39 29 Homepage http www faltcom se Service address F lt Communications AB c o BL Elektronik AB Servi...

Reviews: