Installation Manual Essentials 120213 
 

 

 
 
BEFORE BEGINNING INSTALLATION 
 
SYSTEM REQUIREMENTS 

 
The IAQ Economizer was designed for use with constant speed fans installed on systems using 
conventional thermostats.  The IAQ Economizer can be installed on systems with proprietary or 
communicating thermostats, but these installations will not have the full range of features 
available to a conventional system.  
 
Systems with a modulating fan have several options for installation.  Visit 
famcoiaq.com/MANUALS for wiring with modulating fans.   
 
Visit famcoiaq.com/MANUALS for wiring FAMCO for use with heat pumps. 
 
Verify that the existing system is operating properly.  Initiate a call for cooling and observe 
operation of the blower and condensing unit, and delivery of cooled air. 
 

INSTALLATION 

 

IMPORTANT: Turn off the HVAC system at the breaker box before beginning installation.

 

Do not use the existing furnace transformer to power the IAQ Economizer.  The furnace 
transformer is not sized to support proper economizer operation.   
 
Straightness of ductwork matters.  Avoid sharp bends in ductwork.  Watch out for flex duct 
that may become misshapen if required to turn close to the connection to the damper box.   

Proper operation requires that at a minimum an equal amount of air passes over the 
evaporator coil as in normal return air operation.  Insure that air volume is not negatively 
impacted by the installation of damper box.  

It is the installers’ responsibility to insure the 

appropriate volume of air is available.  Poor installation may adversely affect available air 
volume and could damage HVAC system.

 

 
Do not allow the thermostat “Fan call” to run the blower fan below the mechanical cooling 
speed as this will result in poor performance.  In the case of free-cooling, more air is better.   
 
 
 

Summary of Contents for ECONOMIZER BREATHE SMARTER

Page 1: ...Installation Manual Essentials 120213 BREATHE SMARTER TM PATENT PENDING...

Page 2: ...g HVAC system is functioning properly before beginning installation 4 Place damper box in the location where it will be installed 5 Install outside air intake louver transition and connect flex duct t...

Page 3: ...TANT Turn off the HVAC system at the breaker box before beginning installation Do not use the existing furnace transformer to power the IAQ Economizer The furnace transformer is not sized to support p...

Page 4: ...CAN BE EASILY ACCESSED BY OCCUPANT OUTSIDE AIR TEMPERATURE THERMOSTAT EXISTING FURNACE BOARD OUTSIDE AIR FLEX DUCTWORK ADDED NOT PROVIDED IN KIT IMPORTANT MINIMIZING TURNS AND BENDS IN DUCTWORK IS CRI...

Page 5: ...duct from the intake transition to the FRESH AIR port on the Damper Box Cut the main return duct in a location that will allow re connection to the damper box The damper box will replace a section of...

Page 6: ...VAC only Other sources of power will damage the unit DO NOT power the unit with power from the AC unit The furnace transformer will not have sufficient capacity to provide for the IAQ Economizer Provi...

Page 7: ...T cable are terminated correctly before plugging it into the Logic Box Connect the Power Cable to the Logic Box IMPORTANT There is one auxiliary connection that is required for the Logic Box to functi...

Page 8: ...Step 1 2 2 efore Furnace Board After To Logic Box To Thermostat Condensing Unit Yellow Yellow Green Green White Red Condensing Unit Yellow Green Red White To Thermostat Condensing Unit Yellow Yellow...

Page 9: ...Installation Manual Essentials 120213 8 STEP 3 Plug the other end of the furnace cable into the logic box connection marked FURNACE...

Page 10: ...Installation Manual Essentials 120213 9 3 GANG OR SURFACE MOUNT OPTIONS FIGURE 3 3 GANG FLUSH SURFACE E SET SCREW...

Page 11: ...use the Override OVRD switch to initiate an air introduction If the Yellow light went out before you switched the OVRD switch and the Red light lit wait 90 seconds The Green light should light indicat...

Page 12: ...pen the damper box as expected there are four items that should be checked 1 IAQ Economizer switch may be OFF 2 LIMIT Switch is OPEN or no jumper is installed 3 Outdoor thermostat setting requirements...

Page 13: ...Installation Manual Essentials 120213 12 All components of the IAQ Economizer are tested before shipping...

Page 14: ...NSFORMER CAPACITY IS 50VA LOGIC BOX TRANSFORMER TYPICALLY CONSUME LESS THAN 20VA DEVICES USING PWR OUT CANNOT EXCEED 50VA TOTAL TRANSFORMER CAPACITY EXTERNAL DEVICES PROVIDING A POWERED SIGNAL TO THE...

Page 15: ...using AUX START 1 Typical Uses Outdoor air low or high limit outdoor humidity or dew point limit Multiple devices need to be wired in series T2 Input used to allow a different setpoint to call for ec...

Page 16: ...ction is allowed Multiple devices need to be wired in parallel POWER Power simply provides 24 VAC that can be used to power other control devices used with the system The top terminal is 24VAC the bot...

Page 17: ...Installation Manual Essentials 120213 16 AUXILLIARY CONNECTIONS FIGURE 5 LIMIT T2 EXT START 2 PWR OUT HRV INTRUPT EXT START 1 13 NOT USED 12 COMMON 11 ECON SIG 10 COMMON 9 24VAC 8 7 6 5 4 3 2 1...

Page 18: ...LIMIT CONDITIONS MET SYSTEM ON STAT CALLING EXT START 2 ON DAMPER CORRECT OPEN DAMPER S FAN ON COMPRESSOR ON YES YES YES YES YES YES YES NON ECON SUPPORTED COOL CALL YES ERROR INDICATION NO DAMPER PO...

Reviews: