Chapter 6 Function Introduction
Shenzhen Hpmont Technology Co., Ltd.
- 32 -
HD3N-L Series User Manual V1.0
Ref. Code
Function Description
Setting Range [Default]
F05.12
FDT1
0.0 - 100.0 (F00.02) [90.0%]
F05.13
FDT2
0.0 - 100.0 (F00.02) [90.0%]
F05.14
FDT1 delay level
0.0 - 100.0 (F00.02) [1.0%]
F05.15
FDT2 delay level
0.0 - 100.0 (F00.02) [1.0%]
When running speed is lower than one speed (F05.12 +
F05.14) as FL in the right figure, ON indicating signal
will output till the running speed is lower than F05.12.
•
F05.13, F05.15 refer to F05.12 and F05.14.
F05.16
Speed within FAR range
0.0 - 20.0 (F00.02) [1.0%]
If the elevator speed is within the FAR range, a pulse
signal is output.
As shown in the right figure.
F05.17
Over-speed setting
80.0 - 120.0 (F00.02) [115.0%]
F05.18
Over-speed detection time
0.0 - 2.0 [0.2s]
When the actual elevator speed exceeds F05.17, and the duration time exceeds F05.18, HD3N-L alarms
E0032 fault (motor over speed).
•
F05.18 = 0, HD3N-L does not detect motor over speed fault.
F05.19
Detection value of speed deviation
0.0 - 30.0 (F00.02) [20.0%]
F05.20
Detection time of speed deviation
0.0 - 2.0 [1.0s]
When the deviation of setting speed (after Acc. and Dec.) and actual run speed of motor exceeds F05.19,
and the duration time exceeds F05.20, HD3N-L alarms E0018 fault (excessive speed deviation).
•
F05.19 or F05.20 = 0, HD3N-L does not detect the excessive speed deviation fault of motor.
123
6.2.7
F06: Optimize parameters
Ref. Code
Function Description
Setting Range [Default]
F06.19
Brake premature close run time
0.000 - 1.999 [0.000s]
F05.14
F05.12
FL
Elevator speed
Time
Time
DO
ON
ON
OFF
F05
F05
Elevator speed
DO
Setting speed
Setting speed+F15.16
Setting speed-F15.16
Time
Tim