Chapter 6 Function Introduction
Shenzhen Hpmont Technology Co., Ltd.
- 46 -
HD3N-L Series User Manual V1.0
Ref. Code
Function Description
Setting Range [Default]
F19.56 Motorized slip compensation gain
2
00.0 - 20.0 [100.0%]
F19.57 Power generation slip compensation gain
200.0 - 20.0 [100.0%]
F19.63 Start DC current when emergency operation
50 - 100 [70%]
F19.64 Start DC brake time when emergency run
0.0 - 3.0 [0.0s]
F19.65 Stop DC current when emergency run
50 - 100 [70%]
F19.66 Stop DC brake time when emergency run
0.0 - 3.0 [1.5s]
F19.67 Current search and torque limit when emergency run
40.0 - 200.0 [100.0%]
F19.68 Torque boost when emergency run
0.1 - 30.0 [2.0%]
F19.69 Torque boost cut-off point when emergency run
0.1 - 50.0 [40.0%]
F19.70 VF output rated voltage percentage when emergency run
60.0 - 100.0 [100.0%]
F19.88 SVC6 I/F control enable
0,1 [0]
0: Forbidden.
1: Enable.
F19.89 SVC6 I/F control frequency cut-off point
2.00 - 10.00 [4.00Hz]
F19.90 Given SVC6 I/F control torque
0 - 200 [100%]
F19.96 SVC6 I/F control transition optimization
0,1 [1]
0: Normal optimization.
1: Over optimization.
F19.98 SVC5 startup processing
0,1 [1]
0: Normal processing.
1: Over processing.