Shenzhen Hpmont Technology Co., Ltd.
Chapter 7 Elevator Application Guidance
HD3N-L Series User Manual V1.0
- 49
-
Chapter 7
Elevator Application Guidance
It is recommended to analyze the actual application requirements before the wiring design.
Basic configuration for elevator system with HD3N-L is shown in Figure 7-1.
Figure 7-1 Elevator system
7.1
Basic Commissioning Steps
7.1.1
Set Basic Parameters
1.
Correctly set F00.01 (control mode).
2.
Correctly set the motor parameters (group F07).
3.
According to the actual wiring, set the digital input and output function parameters (group F12).
4.
Terminal MS running mode:
•
According to the actual requirement of elevator and the elevator controller, set MS parameters (group
F05).
•
According to the elevator speed, set Acc. and Dec. curve parameters (group F03).
Terminal analogue running mode:
•
According to the actual requirement of elevator and the elevator controller, set analogue curve
parameters (group F04) and analogue input and output function parameters (group F13).
•
The bigger Acc. and Dec. curve parameters (group F03) are set, the quicker HD3N-L catch the speed
command of elevator controller.
HD3N-L
L2
L1
L3
U
V
W
R
S
T
M
Elevator
controller
Input
terminal
Output
terminal
Contactor
7