Appendix A Parameters
Shenzhen Hpmont Technology Co., Ltd.
- 64 -
HD3N-L Series User Manual V1.0
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
D01: Drive Status Parameters (on pages 25 - 25)
D01.00
Control mode
0 - 5
Actual
*
D01.01
Setting speed
0.000 - 9.999m/s
Actual
*
D01.02
Setting speed (after Acc. and
Dec.)
0.000 - 9.999m/s
Actual
*
D01.03
Feedback speed
0.000 - 9.999m/s
Actual
*
D01.04
Setting frequency
0.01 - 100.00Hz
Actual
*
D01.05
Setting frequency (after Acc.
and Dec.)
0.01 - 100.00Hz
Actual
*
D01.06
Output frequency
0.01 - 100.00Hz
Actual
*
D01.07
Setting RPM
0 - 60000rpm
Actual
*
D01.08
Running RPM
0 - 60000rpm
Actual
*
D01.10
Output voltage
0 - 999V
Actual
*
D01.11
Output current
0.1 - 999.9A
Actual
*
D01.14
DC bus voltage
0 - 999V
Actual
*
D02: Analogue Status Display Parameters (on pages 26 - 26)
D02.00
AI voltage
0.00 - 10.00V
Actual
*
D02.01
AI voltage (after calculating)
0.00 - 10.00V
Actual
*
D02.08
AO output
0.00 - 10.00V
Actual
*
D03: Running Status Parameters (on pages 26 - 27)
D03.01
Input terminal status
The standard LCD display is
hexadecimal number, and the
optional LCD display is a 16-bit
binary number
Bit0 - Bit7: DI1 - DI8
Actual
*
D03.02
Output terminal status
The standard LCD display is
hexadecimal number, and the
optional LCD display is a 16-bit
binary number
Bit0 - Bit1: DO1, DO2
Bit2 - Bit3: RLY1, RLY2
Actual
*
D03.03
Modbus status
0: Normal
1: Communication timeout
2: Incorrect data frame head
3: Incorrect data frame
checking
4: Incorrect data frame
content
Actual
*
D03.04
Total time at power-on (h)
0 - 65535h
Actual
*
D03.05
Total running time (h)
0 - 65535h
Actual
*
D03.06
Running times
0 - 65535h
Actual
*
D03.07
Present fault
0 - 65535
Actual
*