Appendix A Parameters
HD3N-L Series User Manual V1.0
- 75
-
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F19.53
Modify automaticly updated
mutual inductance of no-
load current
0: Change automatically
1: No change automatically
0
1
×
F19.55
Enable about the
compensation gains of the
electric and power
generation slip are
compensated separately
0: Disenable
1: Enable
0
1
×
F19.56
Motorized slip compensation
gain
200.0 - 20.0%
100.0%
0.1%
×
F19.57
Power generation slip
compensation gain
200.0 - 20.0%
100.0%
0.1%
×
F19.63
Start DC current when
emergency operation
50 - 100%
70%
1%
×
F19.64
Start DC brake time when
emergency run
0.0 - 3.0s
0.0s
0.1s
×
F19.65
Stop DC current when
emergency run
50 - 100%
70%
1%
×
F19.66
Stop DC brake time when
emergency run
0.0 - 3.0s
1.5s
0.1s
×
F19.67
Current search and torque
limit when emergency run
40.0 - 200.0%
100.0%
0.1%
×
F19.68
Torque boost when
emergency run
0.1 - 30.0%
2.0%
0.1%
×
F19.69
Torque boost cut-off point
when emergency run
0.1 - 50.0%
40.0%
0.1%
×
F19.70
VF output rated voltage
percentage when emergency
run
60.0 - 100.0%
100.0%
0.1%
×
F19.88
SVC6 I/F control enable
0: Forbidden
1: Enable
0
1
×
F19.89
SVC6 I/F control frequency
cut-off point
2.00 - 10.00Hz
4.00Hz
0.01Hz
×
F19.90
Given SVC6 I/F control torque 0 - 200%
100%
1%
×
F19.96
SVC6 I/F control transition
optimization
0: Normal optimization
1: Over optimization
0
1
×
F19.98
SVC5 startup processing
0: Normal processing
1: Over processing
0
1
×
A