Appendix A Parameters
Shenzhen Hpmont Technology Co., Ltd.
- 76 -
HD3N-L Series User Manual V1.0
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F20: Function-boost Parameters 2 (on pages 47 - 47
F20.00
Start DC brake current
50 - 150%
100%
1%
×
F20.01
Duration of start DC brake
current
0.0 - 3.0s
0.0s
0.1s
×
F20.02
DI enable function
0: Original plan
1: New plan
0
1
×
F20.03
Output contactor open time
0 - 9s
0s
1s
×
F20.04
Ground detection before
running
0: Detection
1: No detection
0
1
×
F20.05
Brake open frequency
0.00 - 10.00Hz
0.00Hz
0.01Hz
×
F20.06
Brake open current
0 - 150%
0%
1%
×
F20.07
Restore customized
parameters
0 - 9
0
1
×
F20.13
Emergency run torque limit
70.0 - 200.0%
0.0%
0.1%
×
F20.14
Emergency run undervoltage
point setting
160 - 220V
190V
1V
×
F20.15
Emergency run parameter
Unit: Unused
Ten: Emergency run torque
limited (F20.19)
0: F20.19 no functional
1: F20.19 functional
Hundred: Emergency run
mode determine
0: F00.01
1: V/f control
110
1
×
F20.17
Search speed of light load
current method when
emergecy run
0.020 - 0.200m/s
0.150m/s
0.001m/s
×
F20.18
Search time of light-load
current method when
emergency run
0.300 - 3.000s
0.500s
0.001s
×
F20.19
Emergency run torque
limited
70.0 - 200.0%
100.0%
0.1%
×