Shenzhen Hpmont Technology Co., Ltd.
Chapter 6 Function Introduction
HD3N-L Series User Manual V1.0
- 29
-
6.2.3
F02: Start and Stop Parameters
Ref. Code
Function Description
Setting Range [Default]
F02.00
Start delay time
0.000 - 4.999 [0.000s]
Defines the delay time from the running command to the controller in the running state.
•
F00.05 = 0 (keypad control), F02.00 is invalid.
F02.01
Brake open delay time
0.000 - 4.999 [0.500s]
F02.02
Start zero-speed hold time
0.000 - 4.999 [0.000s]
It defines the time from when the brake is opened to when there is speed output, and the motor has
output torque during this period.
•
It can improve the comfort when starting.
F02.03
Start speed
0.000 - 0.400 [0.030m/s]
F02.04
Start speed hold time
0.000 - 4.999 [0.300s]
F02.05
Brake close delay time
0.000 - 1.999 [0.300s]
Defines the time from when the controller runs from zero speed to when the brake close command is
output.
F02.06
Stop zero-speed hold time
0.000 - 4.999 [0.300s]
Defines the time to keep the motor at zero speed and output torque when stopping.
•
It can improve the comfort when parking.
F02.07
Run contactor close delay time
0.000 - 4.999 [0.000s]
Defines the delayed close time of the run contactor after the running command is cancelled.
F02.08
Starting ramp time
0.001 - 2.000 [0.500s]
It defines the time required for the elevator to accelerate from zero speed to the rated speed (F00.02).
•
Invalid when set to 0.
F02.00 F02.01
F02.08
F02.02 F02.04
F02.03
0
Contactor output
Controller running
Brake
Zero-speed
Zero-speed
F02.05F02.06F02.07
Run command
Speed
Time
Objective speed
6