Shenzhen Hpmont Technology Co., Ltd.
Appendix A Parameters
HD3N-L Series User Manual V1.0
- 65
-
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F00: Basic Parameters (on pages 27 - 28)
F00.00
Motor type
0: Asynchronous motor
0
1
×
F00.01
Control mode
0: V/f control
1: SVC1 control
2 - 4: Unused
5: SVC5 control
6: SVC6 control
1
1
×
F00.02
Elevator rated speed
0.100 - 4.000m/s
1.500m/s
0.001m/s
×
F00.03
Controller Max. output
frequency
5.00 - 100.00Hz
50.00Hz
1.00Hz
×
F00.04
Motor mechanical parameter 10.0 - 6000.0
60.0
0.1
×
F00.05
Operating mode
0: Keypad control
1: Terminal analogue control
2: Terminal MS control
3 - 5: Unused
0
1
×
F00.07
Speed setting of keypad
0.000m/s - F00.02
1.500m/s
0.001m/s
○
F00.08
Run direction
0: The same as run command
1: Opposite to run command
0
1
×
F01: Protection of Parameters (on pages 28 - 29)
F01.00
User’s password
0 - 65535
0
1
○
F01.01
Menu mode
0: Full menu mode
1: Checking menu mode
0
1
○
F01.02
Function parameter
initialization
0: No operation
1: Restore to factory settings
2: Download the keypad
EEPROM parameter to the
current function code settings
3: Clear fault information
0
1
×
F01.04
Keypad EEPROM parameter
initialization
0: No operation
1: Upload the current function
code settings to the keypad
EEPROM parameter
0
1
○
F02: Start and Stop Parameters (on pages 29 - 30)
F02.00
Start delay time
0.000 - 4.999s
0.000s
0.001s
×
F02.01
Brake open delay time
0.000 - 4.999s
0.500s
0.001s
×
F02.02
Start zero-speed hold time
0.000 - 4.999s
0.000s
0.001s
×
F02.03
Start speed
0.000 - 4.000m/s
0.030m/s
0.001m/s
×
F02.04
Start speed hold time
0.000 - 4.999s
0.300s
0.001s
×
F02.05
Brake close delay time
0.000 - 1.999s
0.300s
0.001s
×
F02.06
Stop zero-speed hold time
0.000 - 4.999s
0.300s
0.001s
×
F02.07
Run contactor close delay
time
0.000 - 4.999s
0.000s
0.001s
×
F02.08
Starting ramp time
0.001 - 2.000s
0.500s
0.001s
×
A