Appendix A Parameters
HD3N-L Series User Manual V1.0
- 71
-
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F15.02
Set run status parameter 1
0 - 3: Unused
4: Setting speed
5: Setting speed (after Acc.
and Dec.)
6: Output frequency
7: Setting RPM
8: Running RPM
9: Unused
10: Output voltage
11: Output current
12 - 13: Unused
14: DC bus voltage
15: AI voltage
16: AI voltage (after
calculating)
17 - 22: Unused
23: AO output
24 - 25: Unused
26: Input terminal status
27: Output terminal status
28 - 30: Unused
5
1
○
F15.03
Set run status parameter 2
6
1
○
F15.04
Set run status parameter 3
10
1
○
F15.05
Set run status parameter 4
11
1
○
F15.06
Set run status parameter 5
0
1
○
F15.07
Set run status parameter 6
0
1
○
F15.08
Set stop status parameter 1
4
1
○
F15.09
Set stop status parameter 2
14
1
○
F15.10
Set stop status parameter 3
16
1
○
F15.11
Set stop status parameter 4
26
1
○
F15.12
Set stop status parameter 5
27
1
○
F15.13
Set stop status parameter 6
0
1
○
F16: Function-boost Parameters (on pages 42 - 43)
F16.00
Zero-speed running signal
delay time
0.00 - 10.00s
0.30s
0.01s
×
F16.01
Zero-speed signal delay time 0.00 - 10.00s
0.30s
0.01s
×
F16.02
Current keep time after stop
0 - 9999ms
0ms
1ms
×
F16.03
Fan control
0: Auto stop
1: Immediately stop
2: Run when power on
0
1
○
F16.04
Fan control delay time
0.0 - 600.0s
30.0s
0.1s
○
F16.05
rake unit action voltage
630 - 750V
720V
1V
×
F16.06
Contactor fault detection
time
0.1 - 10.0s
2.0s
0.1s
×
F16.07
Multi-speed inspection
0 - 7
0
1
×
F16.08
Zero-speed threshold
0.001 - 0.010m/s
0.003m/s
0.001m/s
○
F16.09
Selection at motor overheat
fault
0: Alarm fault after motor
stops
1: Alarm fault at once
0
1
○
F16.12
elay time of run output signal 0.00 - 1.00s
0.00s
0.01s
×
F16.13
Emergency run direction
auto-determine enable
0: Not enable
1: Determine the running
direction according to the
current
0
1
×
F16.14
Running Min. current limit
0 - 100% (F07.11)
20%
1%
×
F16.15
Running Min. detection time
0.0 - 5.0s
0.0s
0.1s
×
A