Chapter 6 Function Introduction
Shenzhen Hpmont Technology Co., Ltd.
- 30 -
HD3N-L Series User Manual V1.0
6.2.4
F03: Acc. and Dec. Parameters
Ref. Code
Function Description
Setting Range [Default]
F03.00
Acc. speed
0.020 - 9.999 [0.700m/s
2
]
F03.01
Start Acc. jerk
0.020 - 9.999 [0.350m/s
3
]
F03.02
End Acc. jerk
0.020 - 9.999 [0.600m/s
3
]
F03.03
Dec. speed
0.020 - 9.999 [0.700m/s
2
]
F03.04
Start Dec. jerk
0.020 - 9.999 [0.600m/s
3
]
F03.05
End Dec. jerk
0.020 - 9.999 [0.350m/s
3
]
F03.00 - F03.05 adjust the elevator speed via S-curve. It can cushion the shock at elevator start/stop and
improve riding comfort.
•
See the right figure for the adjustment of
S-curve.
•
The S-curve becomes steeper when
parameter values are raised.
•
The S-curve becomes slower when
parameter values are decreased.
F03.06
Inspection Acc. speed
0.020 - 9.999 [0.200m/s
2
]
F03.07
Inspection Dec. speed
0.020 - 9.999 [1.000m/s
2
]
Defines the Acc. and Dec. speed of the elevator in inspection run mode.
F03.08
Emergency run Acc. speed
0.020 - 9.999 [0.200m/s
2
]
F03.09
Emergency run Dec. speed
0.020 - 9.999 [0.200m/s
2
]
Defines the Acc. and Dec. speed of the elevator in emergency run mode.
F03.10
Motor auto-tuning Acc. speed
0.020 - 9.999 [0.100m/s
2
]
F03.11
Motor auto-tuning Dec. speed
0.020 - 9.999 [0.100m/s
2
]
Defines the Acc. and Dec. speed of the elevator in motor auto-tuning.
F03.13
Stop Dec. jerk
0.020 - 9.999 [0.350m/s
2
]
Defines the deceleration speed from non-zero speed to zero speed.
•
It can adjust the smooth stop of the elevator and add riding comfort.
123
0
Speed
Objective
speed
Time
F03.02
F03.04
F03.01
F03.05
F03.00
F03.03
F03.13