IV FAULT SELF-CHECK METHOD
3.10 Various Timing Operations of The App
3.10.2 Timer Cleaning Mode Set the device to clean regularly in the App "Clean Timing".
3.10.3 Timing Odor Removing: Set the device to remove odor regularly in the App
"Deodo Timing".
4.2 Testing Mode:
①
Press each key to check whether the key works properly. If it works properly, the PCB
hardware is functioning correctly.
②
Press the device from the top with a force of more than 2.2 lb (1kg) to see whether the
"Full" indicator flashes. If it does, the gravity sensor is functioning correctly.
③
If the Bin indicator keeps lighting up, the motor is working correctly.
④
If the WiFi indicator keeps lighting up, the WiFi hardware is functioning correctly.
⑤
Cover the infrared sensor at the barrel entrance, if the "Auto" mark flashes, the sensor
functions correctly.
4.3 Restart the device after the testing mode is completed.
Notice:
Suppose the execution time of these scheduled procedures overlaps with the DND
(Do not Disturb). In that case, the product will first perform odor cleaning and then
return to DND mode.