with the wiring rules. 

Example: If a fan is connected to a circuit that can be isolated via an 

all-pole safety switch at the switchboard, then this is considered to be 

an all-pole disconnection to the ceiling fan electrical circuit, meeting the 

requirements of clause 7.12.2 of AS/NZS 60335.1.   

A single-pole switch on the active of the receiver input of remote 

control must also be included in the wiring, and located the same 

room as the ceiling fan.

 

4. 

        Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. 

Contact  your  local  government  for  information  regarding  the  collection  systems  available.  If  electrical 

appliances are disposed of in landfills or dumps, hazardous substances can leak into the ground water 

and get into the food chain, damaging your health and well-being. 

5. 

The structure to which the fan is to be mounted must be capable of supporting a weight of 23kg. 

6. 

The fan should be mounted so that the blades are at least 2.1m above the floor.   

7. 

This  fan  is  suitable  for  indoor  use only.  Mounting  the  fan  in  a  location  where  it  is  subject  to  water  or 
moisture is dangerous and may increase the risk of damage, injury or electrical shock and will void the 
warranty. 

8. 

Must be assembled and installed by a licensed electrician. 

9. 

WARNING:

 If unusual wobbling or oscillating movement is observed, immediately stop using the ceiling 

fan and contact the manufacturer, its service agent or suitably qualified persons. 

10. 

The replacement of parts of the safety suspension system device shall be performed by the manufacturer, 

its service agent or suitably qualified persons. 

11. 

The  fixing  means  for  attachment  to  the  ceiling  such  as  hooks  or  other  devices  shall  be  fixed  with  a 

sufficient strength to withstand 4 times the weight of the ceiling fan; that the mounting of the suspension 

system shall be performed by the manufacturer, its service agent or suitably qualified persons. 

12. 

The  light  source  contained  in  the  luminaire  is  non-user  replacable.  It  shall  only  be  replaced  by  the 

manufacturer or his service agent or similar qualified person. 

13. 

  

caution, risk of electric shock 

Summary of Contents for NEXUS

Page 1: ...V1 0 AU 07 2022 FANAWAY NEXUS DC CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION...

Page 2: ...lar AC ceiling fans usually come with only 3 speeds this DC fan comes complete with a 6 speed remote which gives a greater choice of comfort levels SAFETY PRECAUTIONS 1 The appliance is not intended f...

Page 3: ...be mounted so that the blades are at least 2 1m above the floor 7 This fan is suitable for indoor use only Mounting the fan in a location where it is subject to water or moisture is dangerous and may...

Page 4: ...n has been damaged during transport Do not operate install any product which appears damaged in any way Return the complete product to the place of purchase for inspection repair or replacement Examin...

Page 5: ...of carrying a load of at least 23kg with two long screws provided Ensure at least 30mm of the screw is threaded into the support Fig 2 NOTE The bracket screws provided are for use with wooden structu...

Page 6: ...they are required to reassemble later 2 Loosen the set screws 11 on the down rod coupling housing 8 Fig 4 2 3 Carefully feed the fan wires 1 up through the down rod 6 fig 4 3 4 Assemble the down rod...

Page 7: ...ver the down rod 6 and install the ball joint 2 and dowel pin 3 back onto the down rod 6 and secure by tightening the set screws 4 Fig 4 5 and Fig 4 6 HANGING THE FAN Lift the fan assembly onto the mo...

Page 8: ...EIVER TO PAIR TOGETHER NOTE Ensure the motor earth wire is connected to the single earthing terminal block 1 in the diagram below Fig 7 From mains supply to mounting bracket terminal block Fig 7 1 Con...

Page 9: ...Installation Instructions 8 P a g e Carefully insert the Remote Receiver above the hanger ball in the remainder spacing in the mounting bracket Take care not to damage or loosen any of the wiring Fig...

Page 10: ...e 2 screws at the bottom of the mouthing bracket 2 Slide the canopy up to the mounting bracket and align the key holes on the canopy with the screws on the mounting bracket Turn the canopy until it lo...

Page 11: ...n or light is turned off by the isolating switch over 7 seconds the next time to turn on the fan or light will be on last setting the light color also will be on the last setting if continue to short...

Page 12: ...of a few centimetres is quite acceptable and DOES NOT suggest any problem TO REDUCE THE FAN WOBBLE Please check that all screws which fix the mounting bracket and down rod are secure NOISE When it is...

Page 13: ...ed Dispose of exhausted batteries immediately and safely so they cannot be retrieved by children Batteries can still be dangerous Contact your local council to safely dispose of the battery Regularly...

Page 14: ...ng or maintenance using inappropriate cleaning products E Defects caused by normal wear and tear accident negligence alteration or misuse F A product dismantled repaired or serviced by any serviceman...

Page 15: ...e entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods...

Reviews: