Aura 37
Installer settings
22
Change password
installer
Setting of a password to protect installer settings from use by non-authorised users.
The password must contain four numbers.
Enter code
0000
to deactivate the password protection.
When the correct password has been entered, all installer screens can be
accessed.
The system will request the password again, if the controller is not used for a few
minutes.
C
ommunication
FNet is the Fancom Network. Several control computers can be linked via this network. FNet is also used to
operate the connected control computers from a PC.
Master - Slave
Master/Slave setting. If the control computer is included in a network, only one control
computer in the network must be set as
MASTER
. Set all the other control computers
as
SLAVE
.
Sent / receive counter
Readout the number of transmitted messages (
Sent counter
) and readout of the
number of received messages (
Receive counter
). (no PC-messages).
These counters can be used to trace faulty communication connections. In
this case set all the counters on all the computers to "0". Normally these
counters increase simultaneously. Communication has failed between the
last computer where the counters are increasing simultaneously, and the
first computer where the counters are not increasing at the same speed.
S2S Status
Readout if the controller is part of the Fancom network:
<5: registering on the network
5: registered on the network
127: no network available