Aura 37
Installer settings
23
See the book 'Aura Principles of climate management' for more information about the influences.
Influence low / high outside temperature on the end temperature ventilation
On end temp ventilation
Setting if the low / high outside temperature must influence the end temperature
ventilation (
YES
/
NO
).
Influence factor
Setting of the factor used by the control computer to calculate the influence (1.0 to
2.0).
1.0: No effect
2.0: Large effect
Influence maximum
Readout of the maximum difference between the
Start temperature ventilation
and
End temperature ventilation
(°C).
Influence calculation
Readout of the actual calculated influence (°C).
Influence factor
:
1.5
Influence maximum
:
4.0°C
The maximum difference between
Start temperature ventilation
and
End
temperature ventilation
is (1.5 x 4.0) = 6.0°C.
Influence high relative humidity on the minimum ventilation
On minimum ventilation
Setting if the high relative humidity must influence the minimum ventilation (
YES
/
NO
).
Influence maximum
Setting of the maximum influence for the minimum ventilation.
Influence calculation
Readout of the actual calculated influence (%).
Minimum ventilation
:
10% (user setting)
Influence maximum
:
5%
The minimum ventilation can increase to maximum 15%.