Aura 37
Installer settings
25
Water / Feed / Aux
Input type
Setting indicating the analog control type (
NONE
/
INPUT
).
Input number (digital)
Readout of the sensor input number.
Amount per pulse
Setting of the amount that corresponds to one pulse.
Tap
to set more settings of the selected output.
General
Output type
Setting indicating the analog control type:
Heating 1 (
NONE
,
ON-OFF
,
Modulating
,
Mixing valve
)
Heating 2 (
NONE
,
10-0V
,
0-10V control
) (only settable if no tunnel-inlet is used)
Exhaust fan, Sidewall-inlet, Tunnel-inlet (
NONE
,
10-0V control
,
0-10V control
,
Modulating 10-0V control
,
Modulating 0-10V control
) (Tunnel-inlet is only settable
if no heating 2 is used)
Cooling, Humidification (
NONE
,
ON-OFF
,
Modulating
)
Output number (analog /
relay)
Readout of the output number.
Sensor selection
Setting on which temperature sensor the control output will operate (
NONE
/
SENSOR 1
/
SENSOR 2
/
SENSOR 1+2
).
Repeat time (mm:ss)
Setting of the time (minutes and seconds) after which the controller should repeat the
calculating and registration between the set and measured values each time.