When using T-inlets, the house sizes are required to be able to calculate the airspeed
during T-phase.
House length
Setting of the length of the house.
House width
Setting of the width of the house.
Wall height
Setting of the height of the side walls of the house.
Roof height
Setting of the ridge height of the roof of the house.
Combi-control
Setting of the speed of progression to the next or previous position in the combi-table.
Choose from
SLOW
/
MODERATE
/
FAST
.
Select
SLOW
if the transitions follow too quickly in succession. If it takes too long before
the control computer proceeds to another position select
FAST
.
Delay MT->T
Setting of the delay for transition from MT- to T-position. During the set time the control
computer will not change the exhaust at this transition.
This delay does not apply with the transition from T to MT (direct control).
Actual combi step