Lumina 38
Installer
38
INSTALLER
→
VENTILATION
→
SETTINGS
→
tab page
M/MT-Part
Description
Setting of the name of the function.
Output address
Setting of the analog output address.
Analog type
Setting indicating the analog control type
Extra analog
Setting of the analog output address.
Position wind side
Setting of the compass positions, which represent the wind side of the house. If the
wind comes from this direction (positions), the ventilation control may be influenced.
Position lee side
Setting of the compass positions, which represent the lee side of the house. If the wind
comes from this direction (positions) under wind side, the ventilation control may be
influenced.
Modulating
Setting indicating the required modulation type (
NONE
/
OPTIMAL
/
FIXED TIME
/
MICRO CTRL
).
Modulating: NONE
Do not use modulating fans.
Modulating: OPTIMAL
*
Modulate below %
*
Setting of the ventilation percentage, below which the control computer will apply
modulating control to the linearly controlled part.
Optimum ON-time
*
Setting of the ON time the control computer tries to achieve (this
ON time
is minimum
15 seconds).
Maximum cycle time
*
Setting of the maximum duration of a cycle (
ON
plus
OFF
period).
Calculated cycle time
*
Readout of the actual cycle time.
Calc.ON/OFF time
*
Readout of the actual
ON/OFF time
.