Lumina 38
Installer
41
INSTALLER
→
VENTILATION
→
INLETS
→
tab page
Inlet
Description
Setting of the name of the function.
Temp. inputs
Setting the addresses of the analog inputs. If the temperature sensors have not been
assigned, the control computer will use the house temperature.
Output address
Setting of the analog output address.
Analog type
Setting indicating the analog control type
Pre-run time
Setting of the time in which the air inlets go to the required position, before the fans
activate.
Modulate link
Setting indicating if these air inlets are to be included in modulating ventilation
— if
modulating ventilation is used.
Position wind side
Setting of the compass positions, which represent the wind side of the house. If the
wind comes from this direction (positions), the ventilation control may be influenced.
Position lee side
Setting of the compass positions, which represent the lee side of the house. If the wind
comes from this direction (positions) under wind side, the ventilation control may be
influenced.
INSTALLER
→
VENTILATION
→
INLETS
→
tab page
Tunnel
Description
Setting of the name of the function.