Lumina 38
Installer
48
Reg. Input
Setting the type of measurement:
•
MANUALLY
: Enables you to enter the amount of today manually.
•
SLOW PULSE
: Measuring instruments with a maximum frequency of 20 pulses per
second (20 Hz).
•
QUICK PULSE
: Measuring instruments with a maximum frequency of 20 pulses per
second (20 Hz) (only use when there is a link with a switch clock).
•
CONTACT
: As long as the sensor makes contact, the value will be added up
cumulatively. The amount is therefore determined by time the contact is
HIGH
.
Amnt per pulse
Setting of the unit that corresponds to one pulse. (only with measurement type:
SLOW
PULSE
or
QUICK PULSE
)
Amount per min.
*
Setting of the number of 'units' measured per minute. This option is only available if
Display=AMOUNT
. (only with measurement type:
CONTACT
)
Display amount
*
Setting how the unit is displayed:
•
AMOUNT
: number 'units' per minute (
Amount per min.
).
•
TIME
: the time the contact makes contact. (only with measurement type:
CONTACT
)
Amount today
Readout of the unit measured today. Reset this value to start all registration from zero
again.
Input status
*
Readout of the actual input status.
HIGH
or
LOW
. (only with measurement type:
CONTACT
)
The control computer requires input from several sensors to determine the climate in the house.
INSTALLER
→
INSIDE CLIMATE
Temp
.
inputs
Setting of the analog temperature inputs. If the
H
option behind the address of the input
is selected, half house brooding is activated for this section.
Pressure input
Setting the address of the analog input.
Block pressure influence
Setting to block the pressure influence (e.g. Free Range House)
Summary of Contents for LUMINA 38