Lumina 38
Installer
49
Speed press. contr.
Setting of the speed at which the control computer determines influences (
SLOW
/
MODERATE
/
FAST
).
Input <x> measurement
where x is RH, NH3 or
CO2
Setting the address of the analog input.
Speed <x> control
where x is RH, NH3 or
CO2
Setting of the speed at which the control computer determines influences (
SLOW
/
MODERATE
/
FAST
).
The control computer can receive input from various sensors to determine the outside climate conditions. These
measurements can also be done by another control computer in the network.
INSTALLER
→
OUTS. CLIMATE
Measurement outside
temp.
Setting if the control computer carries out outside measurement concerned itself (
INT
)
or via the communication network (
COMM
). Only enter the address of the input if INT is
selected.
Address
Setting the address of the analog input.
Measurement outside
RH
Setting if the control computer carries out outside measurement concerned itself (
INT
)
or via the communication network (
COMM
). Only enter the address of the input if INT is
selected.
Address
Setting the address of the analog input.
Measurement wind
Setting if the control computer carries out outside measurement concerned itself (
INT
)
or via the communication network (
COMM
). Only enter the address of the input if INT is
selected.
Input wind speed
Setting of the address of the digital input.