background image

- 1 -

BIS-410-LED 

24 V

Bistable relay

with timer

Electronic bistable pulse relay BIS-410 allows switching on or off 

the lighting or other device from several different points by pa-

rallel connected, momentary (bell) control switches.

Version with the "LED" index has a contact adapted to 

work with receivers with high starting current, such as 

LED lamps, ESL fl uorescent lamps, electronic transfor-

mers, discharge lamps, etc.

The receiver is switched on after a current pulse caused by pres-

sing any momentary (bell) button connected to the relay.

The receiver is turned off after the next impulse or automatically 

after the set off time.

A longer pressing of the momentary button (lasting at least 2 

seconds) turns on the relay permanently.

Purpose

Functioning

F&F Filipowski sp. j.

Konstantynowska 79/81, 95-200 Pabianice, POLAND

phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71

www.fif.com.pl; e-mail: biuro@fif.com.pl

Do not dispose of this device in the trash along with other waste! 

According to the Law on Waste, electro coming from households free of charge and can 

give any amount to up to that end point of collec� on, as well as to store the occasion of 

the purchase of new equipment (in accordance with the principle of old-for-new, regard-

less of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the 

environment and human health.

Summary of Contents for BIS-410-LED

Page 1: ...ff after the next impulse or automatically after the set off time A longer pressing of the momentary button lasting at least 2 seconds turns on the relay permanently Purpose Functioning F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Donotdisposeofthisdeviceinthetrashalongwithotherwaste According to ...

Page 2: ...t relay in the flush mounted box 3 Connect the power supply cables to PWR group wire to terminal 5 or 6 and wire to terminal 3 or 4 4 Momentary switches connected in parallel connect to terminal 1 and wire 5 Connect the powered receiver in series to terminal 2 and wire 6 Set the switch off time with the potentiometer Mounting Wiring diagram ...

Page 3: ...aximum load current AC 1 16 A 120 A 20 ms activation delay 0 1 0 2 s switch off time adjustable 1 15 min power indication green LED power consumption standby 0 15 W on 0 7 W terminal 2 5mm screw terminals tightening torque 0 4 Nm working temperature 25 50 C dimensions 54 size 48 43 mm h 25 mm mounting in flush mounted box 60 ingress protection IP20 Technical data ...

Page 4: ...ion visit www fif com pl The F F products are covered by a warranty of the 24 months from the date of purchase Effective only with proof of purchase Contact your dealer or directly with us F F Filipowski sp j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Dec...