background image

- 5 -

power supply 

165÷265 V AC

contact 

separated 1×NO

maximum load current (AC-1) 

16 A (120 A/20 ms)

control pulse current 

5 mA

activation delay 

0.1÷0.2 s

power supply indication 

green LED

activation indication 

red LED 

mechanical life of the button 

10⁶

cycles

power consumption

stand-by 

0.15 W

on 

0.6 W

terminal 

2.5 mm² screw terminals

tightening torque 

0.4 Nm

working temperature 

-25÷50°C

dimensions 

1 module (18 mm)

mounting 

on TH-35 rail

ingress protection 

IP20

Technical data

Summary of Contents for BIS-411B-LED

Page 1: ...rn the relay contact will be set to off This prevents the controlled receivers from being switched on automatically without supervision after a prolonged power failure The button on the housing performs exactly the same function as the external button connected to the terminals of the device Purpose Functioning F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 2...

Page 2: ...he relay on a rail in the control box 3 Connect the power wires to terminals 1 3 according to the se lected relay control option control pulse L or N 4 Momentary switches connected in parallel connect to termi nal 6 and to the wire to which terminal 3 is connected 5 Connect the powered receiver in series to terminals 11 12 The maximum total backlight current of all connected buttons must not excee...

Page 3: ... 3 Wiring diagram ...

Page 4: ... 4 1 3 power supply of the relay 165 265 V AC 6 control input 11 12 NO contact active ...

Page 5: ...delay 0 1 0 2 s power supply indication green LED activation indication red LED mechanical life of the button 10 cycles power consumption stand by 0 15 W on 0 6 W terminal 2 5mm screw terminals tightening torque 0 4 Nm working temperature 25 50 C dimensions 1 module 18 mm mounting on TH 35 rail ingress protection IP20 Technical data ...

Page 6: ... F F products are covered by a warranty of the 24 months from the date of purchase Effective only with proof of purchase Contact your dealer or directly with us F F Filipowski sp j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity along...